Chapter 6. Profile
73
The bit values according to the state of FAS.
▶
vl target velocity (Object: 0x6042)
Index
: 0x6042
Function
: Target velocity
Unit
: rpm
Basic format
: 0
Setting range
: -30000 ~ 30000
(- value represents inverse run, + represents normal run, the range varies
by the parameter setting.)