6.1.2 CiA 402 SDO
▶
Error codes (Object: 0x603F)
Index:
0x603F
When the inverter is tripped, this SDO is used to identify the type of the trip.
The table below presents the Error code No. for response to the inverter
trip.
Fault Code
Number
Description
0x0000
None
0x2220
Inverter Overload
0x2310
OverCurrent
0x2330
Ground Fault Current
0x3130
Input Phase Loss
0x3210
Over Voltage
0x3220
Low Voltage
0x4310
Over Heat
0x5000
Hardware Fault
0x6300
Parameter Save Error
0x7001
Cooling Fan Fault
0x9001
External Fault A Contact Input
0x9002
Instance Cut off
0x9003
External Fault B Contact Input
0xFF01
Electronic Themal
0xFF03
Output Phase Loss
0xFF04
Overload Trip
▶
Control word (Object: 0x6040)
Index
: 0x6040
The Bit composition below presents the bit command of the Control Word.
so: Switch on
ev: Enable Voltage
qs: Quick stop
eo: Enable operation
er: Enable ramp
ur: Unlock ramp
rr: Reference ramp
fr: Fault reset
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
nu nu nu nu nu r
nu h
fr
rr
ur er eo qs ev so