204
EP-15 Fluid Level Calibration
The default calibration for the EP-15 Fluid Level is just as accurate as standard
fluid level gauges. If, however, the tank has an irregular shape or greater
accuracy is needed, calibration is recommended. There are three calibration
options: 2-Point, 3-Point and 5-Point.
2-Point Calibration
A 2-point calibration is best suited for rectangular or square-shaped tanks,
where the capacity of the top half of the tank matches the capacity in the
lower half of the tank. In a two-point calibration, you will set two points,
one each for empty and full levels. You can begin calibration at either of
the two points, but we recommend starting with an empty tank. You will
fill the tank to complete calibration.
1. Press
MENU| MENU
, use
↓
↑
to select
NMEA
2000
and press
ENT
.
2. Highlight
B
US
S
ETUP
and press
ENT
, which will open the Bus Configuration
menu. A list of network devices will be at the top of the page.
3. Select the EP-15 Fluid Level and press
ENT
.
4. Press
↓
to select
C
ALIBRATE
and press
ENT
. The Device Calibration menu
will appear. Instructions on Calibration will be listed at the top of the menu.
5. Highlight
N
UM
P
TS
,
press
ENT
and select
2.
Press
ENT
.
6.
Select
F
LUID
L
EVEL
, press
ENT
, then select
E
MPTY
L
EVEL
and
press
ENT
.
7. Make sure the fuel tank is empty, highlight
C
ALIBRATE
and press
ENT
.
The following message will appear:
Empty Level Calibration Completed.
Press
ENT
.
8.
Fill up your tank, highlight
F
LUID
L
EVEL
and press
ENT
.
9.
Select
F
ULL
L
EVEL
and press
ENT
.
Highlight
C
ALIBRATE
and press
ENT
.
10.
The following message will appear
:
Full level Calibration Completed.
Press
ENT
, then press
EXIT
repeatedly to get back to the main display.
Calibrate is highlighted on the device configuration menu (left).
Calibration menu (right) with calibration instructions listed at the top.