5
4
DRYING MODE
• After sterilisation, you can use the drying mode. To do this, press . You can choose between 3 drying modes
- 10, 30, and 50 minutes. Press icon once and the „50” will appear. To change the drying time, press it again -
„10” will appear and again - „30” will appear. After the process is completed, the device will stop working. You
will hear a beep sound three times.
• Wait for the device to cool down. It should cool down for at least 3 minutes. Then unplug the power cord from
the mains and remove the lid (B). Remove the tray, bottles, and accessories from the main container. Wipe all
parts of the steriliser with a dry cloth to prevent a build-up of limescale or residue.
AUTO MODE
• You can use the automatic sterilization and drying mode
AUTO
. The following stages of the device’s operation
are indicated by icons - first , and then drying . The whole process takes about 60 minutes. When the
process is finished, you will hear a beep sound three times.
• Wait for the device to cool down. It should cool down for at least 3 minutes. Then unplug the power cord from
the mains and remove the lid (B).
• Remove the tray, bottles, and accessories from the main container. Wipe all parts of the steriliser with a dry
cloth to prevent a build-up of limescale or residue.
AFTER EACH USE
• Wait for the device to cool down. It should cool down for at least 3 minutes. Then unplug the power cord from
the mains and remove the lid (B).
• Do not remove hot items from the steriliser.
• Wash your hands thoroughly before handling sterilised items.
• If necessary, shake off the excess of water from the items before assembling them.
• The removed items should be used/assembled immediately after the process is finished or sterilised again.
Expressed milk can be stored in a sterilised container, in the fridge for up to 48 hours or in the freezer for up to
3 months. Baby formula should be prep ared immediately before each feeding.
• After each use, pour away any remaining water and rinse the container of the device. Wipe the inside of the
base and container with a cloth to prevent a build-up of limescale or residue.
• After each use, care for the hygiene of the heating plate (remove any limescale by cleaning with vinegar or
citric acid, or wiping with a wet cloth).
• The device can be used again only
about 1 hour
after the last sterilisation.
STORAGE
• Disconnect the device from the mains and clean all parts as recommended above.
• Store the device in a box or in a clean dry place.
• Never store the device when it is wet or dirty.
• Never wrap the power cord around the device.
MAINTENANCE
• After each use, pour away any remaining water and rinse the container of the device. Wipe the inside of the base
and container with a cloth to prevent a build-up of limescale or residue.
• After each use, care for the hygiene of the heating plate (remove any limescale by cleaning with vinegar / citric
acid, or wiping with a wet cloth).
• It is recommended to use boiled or filtered water, as it prevents limescale build-up on the elements of the device.
Descale your steriliser every four weeks (or more often depending on the needs) to ensure that it continues to
work properly. Descaling can be done using the following methods:
Vinegar / Citric Acid
Prepare vinegar / citric acid solution with water in a proportion 3:1. Pour the solution into the base of the device
up to the line marked with a dash (maximum). Leave it in the appliance until the limescale dissolves. Then pour the
solution, rinse the inside of the body thoroughly, and dry. NEVER switch on the device when the solution is inside
the body.
WARNING
• DO NOT use any caustic substances or chemicals for cleaning.
• DO NOT use bleaches or chemical solutions / disinfectant tablets in the steriliser or for the products that will be
sterilised in it.
• DO NOT use soften water in the device.
PROBLEM SOLVING
There are no elements in the set that you can fix yourself. If the device does not work properly, please check:
The steriliser is not
working
• Make sure power cord is plugged into the mains and the plug is securely
inserted into the socket.
• Check the socket by plugging in another appliance.
Excessive steam escaping
from under the lid
• Steriliser was incorrectly assembled or items were incorrectly loaded in steriliser.
Refer to Instructions for Use.
Bottles come out with
marks, drops or residue
• Steriliser needs descaling. Refer to MAINTENANCE.
A cycle takes too long to
complete
• Too much water in steriliser. Use exactly 100 ml for one cycle.
• Only a few items have been put into the device - a small filling will extend the cycle.
Error E1
• No water on the heating plate. Pour 100 ml.
If the device still does not work, consult with your supplier about the options for repair or replacement. To do this,
make sure that:
• The device is packed in its original packaging (recommended).
• You have a receipt or proof of purchase.
Correct Disposal of the Product (Waste of Electrical and Electronic Equipment)
This marking on the product or in related texts indicates that the product should not be disposed
of with other household wastes. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources. For further information on
the recycling of this product, please contact the supplier of the product or the local authorities.
GB