–    For many pages, the  

button permits access to sub-pages (for example, to display the maximum and minimum values recorded). 

–    The sub-page displayed currently is indicated at the bottom left by one of the following icons:

     •  

IN = Instantaneous value 

– Current instantaneous value of the measurement, displayed by default every time the page is changed.

     •  

HI = Maximum instantaneous value 

– Highest value measured by the IP for the corresponding measurement. HIGH values are stored and preserved even in the absence of a power supply. They can be reset

through a dedicated command (see COMMANDS MENU).

     •  

AV = Average value 

– Average value of the measurements, with slowed variations (average of the last minute).

     •  

LO = Minimum instantaneous value 

– Lowest value measured by the IP from the moment voltage is applied. It is reset with the same command used for the HI values.

     •  

GR = Graphic bars 

– Display of measurements through graphic bars.

–    The user can specify the page and sub-page to return to automatically after no buttons have been pressed for a given time.

–    It is also possible to program PMVF 80 so that the display always remains that which was last selected.

–    For the setup of these functions, see MENU M02 – UTILITY.

TABLE OF DISPLAY PAGES

      No.        Selection via  

and

t

                                                                                                                                                                                                        Selection via  

                   PAGES                                                                                                                                                                                                                                        SUB-PAGES

       1          

VOLTAGES, FREQUENCY

                                                                                                                                                            HI                                LO                                AV                                GR

                   V(L1-L2), V(L2-L3), V(L3-L1), F(Hz)

       2          

IP STATE SYNOPTIC

                   STATE OF IS/BACKUP CONTROL OUTPUTS, FEEDBACK INPUT, R.O.C.O.F/VECTOR SHIFT INHIBIT INPUT, 

                   IP DISABLING INPUT, REMOTE TRIPPING

       3          

ACTIVE THRESHOLDS – DELAYS IN USE                                                                                                          

FREQUENCY THRESHOLDS AND DELAYS CURRENTLY ACTIVE

                   VOLTAGE THRESHOLDS AND DELAYS CURRENTLY ACTIVE                                                                            

R.O.C.O.F – VECTOR SHIFT                                                                                 

       4          

IP TRIP COUNTER

                   IS TRIP CNT, BACKUP TRIP CNT, REMOTE TRIP CNT, POWER-ON CNT, IS OFF TIME                                                                                                                                                                            

       5          

VOLTAGE THRESHOLD TRIP COUNTERS

                   U>>, U>, U<, U<< CNT                                                                                                                                                                                                                                                                              

       6          

FREQUENCY THRESHOLD TRIP COUNTERS

                   f>>, f>, f<, f<<, R.O.C.O.F TRIP, VECTOR SHIFT TRIP CNT                                                                                                                                                                                                                       

       7          

PHASE-TO-PHASE VOLTAGES

                                                                                                                                                    HI                                LO                                AV                                GR

                   V(L1-L2), V(L2-L3), V(L3-L1), V(LL)EQV

       8          

PHASE-TO-NEUTRAL VOLTAGES

                                                                                                                                                HI                                LO                                AV                                GR

                   V(L1-N), V(L2-N), V(L3-N), V(L-N)EQV

       9          

MOVING AVERAGE VOLTAGE

                                                                                                                                                     HI                                LO

                   VM(L1-L2), VM(L2-L3), VM(L3-L1) OR VM(L1-N), VM(L2-N), VM(L3-N)                                                                                                                       

      10         

PHASE AND NEUTRAL CURRENTS

                                                                                                                                           HI                                LO                                AV                                GR

                   I(L1), I(L2), I(L3), I(N)

      11         

ACTIVE POWER

                                                                                                                                                                          HI                                LO                                AV                                GR

                   P(L1), P(L2), P(L3), P(TOT)

      12         

ACTIVE POWER IMBALANCE

                                                                                                                                                     HI                                LO                                AV                                GR

                   kW P1-P2, kW P2-P3, kW P3-P1 

      13         

TREND GRAPH

                   P(TOT) LAST 24h                                                                                                                                                                                                                                                                                      

      14         

ACTIVE ENERGY – ACTIVE POWER – BAR GRAPH

                   kkWh (TOT) – kW (TOT) – BAR GRAPH kW(TOT)                                                                                                                                                                                                                                    

      15         

REACTIVE POWER 

                                                                                                                                                                     HI                                LO                                AV                                GR

                   Q(L1), Q(L2), Q(L3), Q(TOT)

      16         

APPARENT POWER 

                                                                                                                                                                   HI                                LO                                AV                                GR

                   S(L1), S(L2), S(L3), S(TOT)

      17         

POWER FACTOR

                                                                                                                                                                        HI                                LO                                AV                                GR

                   PF(L1), PF(L2), PF(L3), PF(TOT)

      18         

ENERGY METERS

                                                                                                                                                                                                                        PARTIAL

                   kWh+(TOT), kWh-(TOT), kvarh+(TOT), kvarh-(TOT), kVA(TOT)

      19         

ENERGY METERS PHASE L1

                                                                                                                                                                                                       PARTIAL

                   kWh+L1(TOT), kWh-L1(TOT)

      20         

ENERGY METERS PHASE L2

                                                                                                                                                                                                       PARTIAL

                   kWh+L2(TOT), kWh-L2(TOT)

      21         

ENERGY METERS PHASE L3

                                                                                                                                                                                                       PARTIAL

                   kWh+L3(TOT), kWh-L3(TOT)

      10         

EVENT LOG

                                                                                                                                                                                                             EVENT SCROLLING (128 EVENTS)

                                                                                                                                                                                                                                                                               

      22         

EXPANSION MODULES

                                                                                                                                                                                                                       

      23         

INFO-REVISION-SERIAL NO.

                   MODEL, REV SW, REV HW, SER. No.                                                                                                                                                                                                 

      24         

LOGO

                                                                                                                                                                                                                                                  

–    

Note:

some of the pages listed above may not be displayed, if the function displayed is not enabled. For example, if external CTs are not connected and programmed, the pages highlighted in grey are not

displayed. 

–    

Note:

the moving average voltage measurement is not available for the first 10 minutes after switching on or resetting the system. During this time, dashes and a countdown indicating the time left before

measurement display are shown.

Summary of Contents for PMVF 80

Page 1: ...den Vor jedem Eingriff am Instrument die Spannungszufuhr zu den Messeing ngen trennen und die Stromwandler kurzschlie en Bei zweckwidrigem Gebrauch der Vorrichtung bernimmt der Hersteller keine Haftun...

Page 2: ...ol OUT1 IS Interface Switch coil control OUT2 backup device control 4 contact digital inputs for INP1 IS feedback input INP2 R O C O F and Vector Shift monitoring function inhibition INP3 interface pr...

Page 3: ...ant information in both numerical and graphical form The limit thresholds are indicated by a small marker above the graphic bar while the arrows under the graphic bar indicate the measurement range HI...

Page 4: ...ACTIVE VOLTAGE THRESHOLDS AND DELAYS CURRENTLY ACTIVE R O C O F VECTOR SHIFT 4 IP TRIP COUNTER IS TRIP CNT BACKUP TRIP CNT REMOTE TRIP CNT POWER ON CNT IS OFF TIME 5 VOLTAGE THRESHOLD TRIP COUNTERS U...

Page 5: ...he settings In the normal measurements display press MENU to recall the main menu then select the password icon and press The password setting window shown below will appear Press the s t buttons to c...

Page 6: ...are used P01 05 Current of CT secondary winding P01 06 Type of connection and type of voltage control Program in line with the wiring P01 07 Rated active power of system If set to AUT the value is ca...

Page 7: ...Threshold 115 P 50kW OFF 100 130 125 P 50kW P04 02 UMAX U Threshold 110 OFF 100 120 P04 03 UMIN U Threshold 80 OFF 20 100 P04 04 UMIN U Threshold OFF P 50kW OFF 5 100 45 P 50kW P04 05 UMAX U Delay s 0...

Page 8: ...Alarm A03 enable ON ON OFF P06 04 Alarm A04 enable ON ON OFF P06 05 Alarm A05 enable ON ON OFF P06 06 Alarm A06 enable ON ON OFF COMMANDS MENU The Commands Menu is used to perform occasional operation...

Page 9: ...A04 INCORRECT MODULE HW CONFIGURATION PMVF 80 has not found the required expansion modules Check that they are configured correctly at the side A05 LSP1 TRIP PRESS s t TO RESTORE Power Imbalance Limi...

Page 10: ...connection of all the ISs auxiliary contacts In single phase wiring connect terminal V3 to VN Class 1 current transformers are recommended ATTENTION terminals A1 and A1 of EXM modules are connected in...

Page 11: ...s selected Backup output mirrors the IS output See parameter P01 16 M01 GENERAL MENU on page 6 TERMINAL LAYOUT MECHANICAL DIMENSIONS MM MOUNTING INSTRUCTION DEMOUNTING INSTRUCTION DEVICE SYMBOLS Warni...

Page 12: ...st be used with the same voltage source TECHNICAL CHARACTERISTICS Auxiliary supply Rated voltage Us 100 240V 110 250V Operating range 85 264V 93 5 300V Frequency 45 55Hz Power consumption dissipation...

Reviews: