Technical data
- 63 -
10.13
Technical data
1
M 200 CuSi
M 250
M 300
Usable wires CrNi
Ø mm
0,8..1,0
0,8..1,0
0,8..1,2
Usable wires CuSi
Ø mm
0,8..1,0
-
-
Wire feed rate
m/min
0,5..25
0,5..25
0,5..25
Mains
Mains voltage 3~ (50/60 Hz)
V
3~ 400
3~ 400
3~ 400
Positive mains voltage tolerance
%
15
15
15
Negative mains voltage tolerance
%
25
25
25
Input power S1 (100 %)
kVA
2,7
3,7
4,5
Input power S1 (60 %)
kVA
4,0
4,5
5,7
Input power S1 (max current)
kVA
7,3
9,8
13,4
Current input I1 (100 %)
A
3,9
5,3
6,5
Current input I1 (60 %)
A
5,4
6,5
8,2
Current input I1 (max. current)
A
10,6
14,2
19,3
Maximum effective mains current
(I
1eff
)
I
1eff
/A
4,7
6,4
8,6
Power factor (at 12max)
cos φ
0,89
0,89
0,89
Mains fuse (slow-response)
A
16
16
16
Mains plug
CEE 16
CEE16
CEE16
Machine
Protection class (in accord-ance with
EN 60529)
IP
23S
23S
23S
Insulation class
F
F
F
Cooling method
F
F
F
Noise emission
dB(A)
< 70
< 70
< 70
Dimensions and weights
Dimensions
mm
880 x 400 x 755
880 x 400 x 755
880 x 400 x 755
Weight
kg
74
71
80
Standard equipment
Feed unit
Rollers
4
4
4
Tab. 3:
Technical data
1
) measured at 40° C environmental temperature
2
) reduced performance at 1~ 230 V operation mode.
Summary of Contents for M-Pro Performance M 200 CuSi
Page 87: ...Puesta en funcionamiento 87 10 13 ...
Page 293: ... 293 10 13 ...
Page 315: ...Antes de colocar em funcionamento 315 10 13 ...