Messages
- 58 -
10.13
In case of failure, a failure code is displayed
in graphical display 49.
As long as there is an error code
on display welding is not possible.
i
15 Messages
Code Error description
Note
Rectification
noP
no program
Instead of material thickness „noP”
is displayed.
Welding is not possible at activated
characteristic line and set welding
step.
Select a different weld
-
ing step
E01
Excessive tempera
-
ture
The equipment has been over
-
heated
Allow the system to cool
down in standby, check
the ventilation system
E02
Mains overvoltage
Mains input voltage too high
Check mains voltage
E03
Overcurrent
Output current is too high / Perma
-
nent short circuit
Inform Service
E06
Overvoltage
Output voltage too high
Inform Service
E07
EEProm checksum
error
Setting data faulty or missing
Switch the equipment
off and on again
E08
Wire feed
Too high power intake from wire
feed motor (Motor Over-Current)
Blow down torch pack
-
age with pressured air
and check pressure on
wire feed rolls.
E09
Voltage-measuring
Voltage measuring system defective Inform Service
E10
Torch connector/-
cable
Welding potential on torch control
cable
Check torch/exchange
E13
Temp. sensor error Thermal sensor not ready for opera
-
tion
Inform Service
E14
Supply voltage
internal supply voltage too low
(18V~ / 24V-)
Check mains voltages
E15
Power measuring
Fault at power measuring
Inform Service
Summary of Contents for M-Pro Performance M 200 CuSi
Page 87: ...Puesta en funcionamiento 87 10 13 ...
Page 293: ... 293 10 13 ...
Page 315: ...Antes de colocar em funcionamento 315 10 13 ...