Messages
- 59 -
10.13
Code Error description
Note
Rectification
E16
Supply voltage
motor and main
contactor
Internal supply voltage is too little
(42V~ / 60V-) /
PE conductor monitoring input
(Fault current to protective earth
conductor)
Check power supply
voltage / Check con-
nection of the workpiece
cable and ground clip,
check for short-circuits
between welding wire
and housing
E17
Peripherie overload/
short circuit
Short circuit in torch or hose pack-
age, gas valve or feed line, wire
run key or line
Test alt. exchange the
connected torch
E18
Error configuration
Faulty or wrong pc-board,
wrong software system played
Inform Service
Tab. 1:
Messages
Summary of Contents for M-Pro Performance M 200 CuSi
Page 87: ...Puesta en funcionamiento 87 10 13 ...
Page 293: ... 293 10 13 ...
Page 315: ...Antes de colocar em funcionamento 315 10 13 ...