Start-up
- 54 -
10.13
Delete job
Â
Press key Tiptronic 50.
Â
Select menu option „delete job” by turning
operation knob 52.
Â
Confirm menu option „delete job” by press
-
ing operation knob 52.
Â
Select the job to be deleted by turning op
-
eration knob 52.
Â
Confirm this job by pressing operation
knob 52.
9
Safety question „delete job?” appears.
Â
Select „YES“ to delete this job by turning
operation knob 52.
Abb. 33: delete job
Â
Confirm „YES“ by pressing operation knob
52.
Â
Press key 46, 50 or 51 to exit menu and
return to standard display
.
13.10 Special functions
Gas test
Â
Turn the unit OFF using main switch 9.
Â
Press the torch key and keep it pressed.
Â
Turn the unit ON using main switch 9.
9
The solenoid valve of the unit will go on
and the gas supply can be tested/adjust
-
ed. The function is active for 30 seconds
and will be automatically stopped. Re-
pressing the torch key. can interrupt the
gas test.
Fan test
Â
Turn the unit ON using main switch 9.
9
The fan will start for function purposes.
Operation panel test
Â
Press the mode key 47 for at least 2 sec
-
onds.
9
The complete display panel of the graphic
display will flash.
Â
Press the key operation mode 47 again.
9
Another display test follows.
Â
Press the key operation mode 47 again.
9
The operation panel test will be initiated.
Â
Press and turn the keys as shown in the
graphic display.
If there is no input for 20 seconds, the op-
eration panel test will be cancelled auto
-
matically.
Summary of Contents for M-Pro Performance M 200 CuSi
Page 87: ...Puesta en funcionamiento 87 10 13 ...
Page 293: ... 293 10 13 ...