Menu structure
- 57 -
10.13
Main menu
Level 1
Level 2
Note
Sprache/
language
Deutsch
Select menu language.
English
...
Characteristics
Manual
All settings can be performed independ
-
antly from a characteristic line.
SG2/3 0,8mm 82/18
Depending on type of model are various
characteristics set in the manu (material-
gas-wire combination).
...
Display Mode
Current and Voltage
Different display settings can be se
-
lected.
Welding voltage
Welding current
Tiptronic
see chapter „Tiptronic” page
Options
Characterist. type
EU
Display in accordance to EU (european)
classification.
AWS
Display in accordance to AWS (American
Weld¬ing Society) classification.
Interval-Welding
On Off
To switch interval welding on/off.
Spot Welding
On Off
To switch spot welding on/off.
Factory Settings
... reset?
No
Yes
Master reset to reset all settings back to
factory settings.
Delete All Jobs?
No
Yes
To delete all jobs.
Diagnosis
Firmware Version
Displays Firmware Version.
Serial Number
Displays serial no.
Configuration
Displays machine configuration.
Operating Hour Coun-
ter
Displays welding time in hours and min
-
utes.
Op. voltages 60/24V
Displays voltages in Volt..
Transf. Temperature
Displays temperature in °C..
Main menu
Level 1
Factory
settings
Range
Note
Parameters
Spot welding time
1,0 s
0,1...10,0 s
Only available in spot
welding mode.
Interval time-Welding
1,0 s
0,1...10,0 s
Only available in interval
mode.
Interval time-Wait
0,2 s
0,1...1,0 s
Gas pre-flow
0,1 s
0,0...10,0 s
Wire creep speed
2,0 m/min
1,0...15,0 m/min
Wire burnback time
100 %
0...300 %
Gas post-flow
0,5 s
0,1...20,0 s
Summary of Contents for M-Pro Performance M 200 CuSi
Page 87: ...Puesta en funcionamiento 87 10 13 ...
Page 293: ... 293 10 13 ...
Page 315: ...Antes de colocar em funcionamento 315 10 13 ...