100
3. Precautions for Use of Battery
1. When the ambient temperature lowers, the capacity of the battery will reduce. If the
charging rate of the battery is too low, the electrolyte may get frozen. Therefore, if
possible, remain the charging rate at 100%, and preserve the temperature as possible,
so as to ensure that the engine can be started up easily in the next day.
2. In areas where the atmospheric temperature is extremely low, please use the battery
which can withstand the cold.
4.6.2 OPERATIONS TO BE CARRIED OUT AFTER COMPLETION OF
WORKS IN EACH DAY
In order to prevent the mud, water or snow on the loader from getting frozen and ensure
that the loader can be used in the next day, be sure to complete the following operations:
1.
Thoroughly clear away the mud, water or snow on the loader, and prevent the
sealing performance from being damaged because mud, water or snow enters into sealed
portion and then gets frozen.
2.
Park the loader on a dry and hard ground. If no such a ground is available, park the
loader on a wood plank. The use of wood plank may prevent the loader from being frozen
to the ground and ensure the normal use in the next day.
3.
At low temperature, the capacity of the battery will reduce obviously as the storage
time lasts. Be sure to cover the battery, or move it to a warm place and install it onto the
loader for working in the next day.
4.6.3 AFTER COLD WEATHER HAS ENDED
After the weather becomes warm as the season changes, please carry out the following
works:
1. The semi-sticky fuel, hydraulic oil and lubricating oil shall be used for all parts.
2. If no permanent anti-freezing fluid is used, be sure to fully drain the water in the water
radiation system, clean up the water radiation system, and then fill the new coolant.
4.7OPERATION UNDER SPECIAL CONDITIONS
4.7.1 OPERATION UNDER EXTREMELY COLD CONDITIONS
If the loader is working in extremely cold weather, protective measures shall be taken to
ensure the normal operation. The following detailed inspection can ensure the normal
operation of the loader at low temperature.
1. Inspect whether correct anti-freezing agent has been added into the cooling system.