-- Settings --
Service code |%
Reset |
>Summer/Winter <|
-- Summer/Winter --
>Winter mode <
-- Summer/Winter --
>Summer mode <
-- Main menu --
Settings
>Information <
Factory level
-- Information --
>Sensors <|
Actuators |
System/SW-Version |%
-- Information --
>Sensors <|
Actuators |
System/SW-Version |%
-- Sensors --
>Door contact ON <|
Grate contact ON |
Release ON |%
-- Sensors --
T Flame 38 |%
T Exhaust 26 |
>T Plug-in 24<|%
-- Sensors --
T Plug-in 24 |%
T Boiler 29 |
>Damper contact OFF<|
page 20
Summer /Winter
select the menu suMMer /WInter in the menu settings by pressing the but-
tons
or
and press the
OK
button once (Figure 36).
the setting can be changed by pressing the buttons
or
(Figure 37/38).
Press button
three times to return to the top level of the menu.
To reduce the heat output in summer, the appliance can be adjusted from WINTER
MODE to SUMMER MODE. This setting puts an upper limit on the adjustment
range of the pellet burner.
• Boiler set-point temperature WINTER 75 °C
• Boiler set-point temperature SUMMER 65 °C
To reduce the heat output in summer, the appliance can be adjusted from WINTER
MODE to SUMMER MODE. This setting puts an upper limit on the adjustment
range of the pellet burner.
• Boiler set-point temperature WINTER 75 °C
• Boiler set-point temperature SUMMER 65 °C
24. Information menu
24. Information menu
to enter the menu InFOrMatIOn from the main menu, select the menu InFOr-
MatIOn by pressing
or
and press the
OK
button once (Figure 39).
Sensors
Passive appliance components such as sensors,
etc.
Actuators
active appliance components such as motors, blo-
wers, etc.
Appliance /SW Version
Display of the pre-set appliance type and of the
installed software version
Operating hours
Display of the total of operating hours as well as
how many operating hours remain until the next
maintenance of the appliance is due.
Sensors
select the menu sensOrs in the menu Information by pressing the button
or
and press the
OK
button once (Figure 41)
Paging through the menu items is possible by pressing the button
or
(Figure 41-44).
On /OFF (OFF = Door open)
On /OFF (OFF = grate open)
On /OFF (OFF = no external command)
Current flame temperature
Current exhaust gas temperature
Current discharge chute temperature
Current boiler temperature
On /OFF (OFF = Operation with firewood)
Press the button
three times to return to the top level of the menu.
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Summary of Contents for Aqua Insert+P