16. Electrical connection
16. Electrical connection
•
Before performing any work on the appliance, the appliance must be disconnec-
ted from the mains supply (Emergency-STOP).
•
Electrical connection work on the appliance must be performed by certified
specialists according to the applicable technical rules, in particular the VDE
guidelines (German Electrical Engineering Association) and the ÖVE guidelines
(Austrian Electrical Engineering Association). We do not assume liability for da-
mage to the appliance resulting from improper connection work; in such a case
the warranty becomes null and void.
•
All electric connecting cables from and to the appliance must be kept away
from hot surfaces of the appliance and of the flue pipe. Do not lay the cable
over sharp edges.
•
Before performing any work on the appliance, the appliance must be disconnec-
ted from the mains supply (Emergency-STOP).
•
Electrical connection work on the appliance must be performed by certified
specialists according to the applicable technical rules, in particular the VDE
guidelines (German Electrical Engineering Association) and the ÖVE guidelines
(Austrian Electrical Engineering Association). We do not assume liability for da-
mage to the appliance resulting from improper connection work; in such a case
the warranty becomes null and void.
•
All electric connecting cables from and to the appliance must be kept away
from hot surfaces of the appliance and of the flue pipe. Do not lay the cable
over sharp edges.
We strongly recommend installing a smoke or fire detector that interrupts the
power supply of the appliance in an emergency.
We strongly recommend installing a smoke or fire detector that interrupts the
power supply of the appliance in an emergency.
•
the appliance is designed to operate only from a 230 V aC/ 50 Hz supply.
Voltage fluctuations of 15 % to +10 % are permissible.
•
the connection is done with a 3-pole power cord (supplied with the appli-
ance).
•
a protective earth conductor is mandatory.
•
When connecting the appliance by means of a plug to a socket, pay attention
to the appropriate polarity (if necessary use a mains plug with anti-rotation
protection) because the appliance must be connected with the correct phase
sequence.
•
the main fuse is a built-in glass cartridge fuse 5x20 2.5 at with ceramic body.
the fuse is located on the main board at the front of the appliance (inside).
•
an emergency stOP switch or an individual safety device must be installed
into the main distribution (for maintenance work, etc.).
If possible connect the supplied power cord to the mains supply prior to installing
the appliance.
If possible connect the supplied power cord to the mains supply prior to installing
the appliance.
Load-bearing capacity of the floor
Prior to installing the appliance, make sure that the substructure of the floor
is suitable for the weight of the appliance. ensure a level and vibration-free
positioning of the appliance.
Room temperature and ambient temperature / humidity
the appliance can be operated in dwellings with normal air humidity and room
temperatures of + 5 °C to + 20 °C.
For room temperatures below 5°C, the water circuit must have an appropriate
anti-freeze.
the appliance is not protected against water spray and must not be installed
in wet rooms.
17. Requirements for the room where the appliance is situated
17. Requirements for the room where the appliance is situated