Downward safety distance
To guarantee correct ventilation, it is necessary to maintain a minimum distance between
the
appliance and an oven, an intermediate shelf or a drawer.
The minimum distance between the lower edge of the hob and
- the upper edge of an oven must be 15mm
- the upper edge of an intermediate shelf must be 15mm
- the bottom of a drawer must be 75mm
Safety distance from the niche covering
If a covering is applied to the niche, a minimum distance must be observed between the
worktop niche and the covering as high temperatures can damage or modify the materials.
If the covering is made of flammable material (e.g. wood), the minimum distance between the
worktop and covering must be 50mm.
If the covering is made of non-flammable material (e.g. metal, natural stone, ceramic tiles),
the minimum distance between the worktop notch and and the covering must be 50mm less
the thickness of the covering.
Example: covering thickness 15mm
50mm - 15mm = minimum distance 35mm
.
Electrical connection
Before making the electrical connection, make sure that the electrical network has
the characteristics indicated on the data plate. Also check that there is an efficient
earthing system according to the law in force.
If the appliance is not supplied with a cable and/or the related plug, apply a
standardised plug with a correct size for the load to be supported.
A direct connection to the line is also possible. In this case it is necessary to
interpose an omnipolar switch with a minimum contact opening of 3 mm, suitable
for the load to be supported and in compliance with the regulations in force (the
earthing conductor not to be interrupted by the circuit breaker).
Absorbed power
see data plate
Connection and protection
The necessary connection data is indicated on the plate and must correspond to that of
the mains.
Determine the various connection possibilities from the relevant diagram.