BASE SETTINGS
Pilot Spindles
At a yarn change (Adjust) the yarn reference value of the first
80 m of yarn are measured and stored with the pilot spin-
dles. Each winding place of the group can be used as pilot
spindle.
Define at least 10% of the spindles of every group as pilot
spindles. For groups of 10 spindles or less, select at least
two pilot spindles.
Data Acquisition
Mode
Last
With the
Last
setting, the current data of a group or
spindle are indicated for the last 100 km, for example.
First
With the
First
setting, the detection of monitor-
ing and classification data of the current production is
stopped at e.g. 100 km
Window Length
(selectable). This
would mean for a group of 50 spindles that the first 2 km
of every spindle are displayed together. With 1000 m/min
spindle speed, 100 km are reached in 2 min.
Cone
With the
Cone
setting, the data of each individ-
ual cone will be shown in the
Monitoring Data
and
Class
Data
menus and automatically deleted after changing.
The current data of the group are displayed for the last
e.g.100 km (Window Length).
Window Length
In
Window Length
, the observation length can be selected
between 10 –1000 km.
Reset Data
Under
Reset Data
the stored
Monitoring Data
and
Class Data
can
be erased. (The shift data are retained.)
•
Activate
Reset
.
•
Enter
Yes
in the message box
“RESET Monitoring Data and
Class Data ?”
.