44
ZENIT
YARN STRUCTURE
Short / Long / Thin Cluster
These settings serve to detect clusters whose individual
faults are nor mally tolerated because they are outside of the
clearing curve. When these faults occur repeatedly over a
short distance, they can still have a negative effect.
To record periodic clusters, a deeper lying curve is defined
for the short, long and thin faults. Faults above or, on the thin
cluster, below these curves, are included in the cluster.
On
/
Off
:
The function of the Short / Long / Thin Cluster
channels can be switched on or off. If a value is entered for
Observation Length
and
Fault
, it is switched on. If
OFF
is select-
ed, it is switched off.
Yarn Count
Count
The wound yarn count is entered here as information. The
yarn numbering system (Nm, NeC, New, Tex, Den) can be
selected in the
Configuration
menu.
Act. DiaDiff
Indicates the effective diameter difference of the yarn signal
of the spindle which started last from the basis.
Summary of Contents for YarnMaster Zenit
Page 1: ...YARNMASTER ZENIT Instruction Manual LZE 044843 003en...
Page 2: ......
Page 4: ......
Page 82: ...w...