36
ZENIT
BASE SETTINGS
Fine Adjust
Mode
Single
After a lot change, the yarn reference value is
measured by a number of pilot spindles. Derived from
this, the reference value is formed and sent to every
other spindle of the group. The individual average value
is then determined over approx. 24 km and adapted, if
required.
Continuous
With Continuous Fine Adjust, the above pro-
cedure is no longer completed. The measured yarn value
is continuously compared to the calculated mean value.
Non-textile changes, such as temperature, yarn tension,
humidity, etc. which infl uence the yarn diameter are being
compensated. Larger deviations from the measured value
(even over a long period of time) trigger an alarm.
Diameter Base
(Group)
Diameter
The determined diameter basis is shown after an Adjust pro-
cess. This value is equivalent to the average yarn signal of
the group.
!
This value should be changed by hand only in special
cases!
Fine Adjust Diff
%
Deviation in percent of the yarn diameter averaged over all
spindles from the basic value (adjustment value).
!
A continuous deviation of this indication means a
yarn count deviation!