66
ZENIT
REPORTS AND DIAGNOSIS
Reports and Diagnosis
Depending on the setting in the
Configuration
menu, the textile, the technical, all or or none alarms are displayed with a message
box on the screen.
Hide
The alarm message is hidden.
Previous
The previous alarm message is displayed.
Clear
The displayed alarm message is deleted
The list of all alarm messages is displayed in the
Dialog
menu.
Textile Alarms
Message
Explanation / Cause
Action
OffCnt Alarm
ShortCnt Alarm
Yarn count off-limit.
Set diameter deviation exceeded.
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone (max. 80 m).
NSLT Alarm
Yarn fault alarm.
Preselected num ber of yarn count startup cuts is
ex ceeded.
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone.
Cluster S Alarm
Cluster L Alarm
Cluster T Alarm
Fault cluster alarm.
Excessive fault accumulation.
Set number of faults exceeded.
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone (max. 80 m).
F Alarm
Foreign matter alarm.
Preselected num ber of foreign matter startup cuts
is ex ceeded.
Clean optics.
Remove bobbin.
Reset spindle alarm and restart spindle.
F Cluster Alarm
Foreign matter cluster alarm.
Preselected number of foreign matter cluster de fects
is exceeded.
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone (max. 80 m).
P Alarm
Foreign matter alarm for synthetic fibers PP, PE, etc.
Preselected number of PP / PE foreign matter cuts
during start-up is exceeded.
Clean sensor.
Remove bobbin.
Reset spindle alarm and restart spindle.
SFI/D Alarm
Surface Index alarm.
Preselected number of SFI/D cuts is exceeded.
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone (max. 80 m).
VCV Alarm
Deviation from determined VCV value.
Preselected number of VCV cuts is exceeded
Remove bobbin.
Reset spindle alarm and restart spindle.
Faulty yarn is auto matically removed from
the cone (max. 50 m).
!
Schlafhorst AC 238/146: In addition remove fault manually from the cone!