50
ZENIT
YARN STRUCTURE
Setting Examples
(Standard Values)
Channel
Cotton and blended yarns short-staple
Insensitive setting
N=6
DS=2.6
LS=1.6
DL=1.32
LL=60
-D=29%
-L=70
Sensitive setting
N=5.5
DS=2.2
LS=1.4
DL=1.26
LL=50
-D=22%
-L=50
Very sensitive setting
N=4.5
DS=2.1
LS=1.3
DL=1.20
LL=40
-D=17%
-L=32
Long-staple yarns
Insensitive setting
N=6
DS=2.6
LS=2.3
DL=1.30
LL=60
-D=30%
-L=70
Sensitive setting
N=6
DS=2.2
LS=2.0
DL=1.22
LL=50
-D=23%
-L=60
Very sensitive setting
N=5.5
DS=1.9
LS=2.5
DL=1.19
LL=45
-D=18%
-L=60
Splice
Sensitive setting
N=OFF
DS=2.2
LS=1.6
DL=1.30
LL=12
-D=OFF
-L=70
CheckLen Splice = 25 cm
Very sensitive setting
N=OFF
DS=2.2
LS=1.3
DL=1.25
LL=12
-D=20%
-L=70
CheckLen Splice = 25 cm
SFI / D
Insensitive setting
Limit
+/– 30%
Sensitive setting
Limit
+/– 25%
Very sensitive setting
Limit
+/– 20%
VCV
Insensitive setting
Limit
+/– 30%
Length
50 m
Sensitive setting
Limit
+/– 25%
Length
20 m
Very sensitive setting
Limit
+/– 20%
Length
10 m
Cluster Short / Long / Thin
Possible setting
Short
Long
Thin
Diameter
DS 1.34
DL 1.12
-D -8%
Length
LS 1.60 cm
LL 16 cm
-L 16 cm
Obs. Length
20 m
12 m
12 m
Faults
55
25
25
If, at the Observation Length of 20 m, the number of Faults is exceeding 55,
the respective spindle will be blocked.
Setting for detection of a defective top roller:
Diameter
DS 1.33
Length
LS 1.30
Obs. Length
20 m
Faults
170