Installation
16
www.loepfe.com
MillMaster TOP
3.3.2
LZE-V
Connect the LZE-V to the client computer
DANGER
Danger of electric shock
Touching live components and electrical connections can lead to severe injury or
death.
4
Unplug the device from mains power before performing any repair or
maintenance work.
4
Unplug the device from mains power before removing device enclosure or
opening side panels.
ü
Use the IP address
192.168.1.200
as the default.
1. Connect the client computer to the LAN 2 port with an RJ45 cable.
ð
The software is now connected to the LZE-V central unit.
LZE-V rear panel
Configure network settings
Prerequisites
ü
The LZE-V has been started up.
1. Open
Settings > Machine > Base settings
.
2. Press
.
ð
The login window opens.
3. Enter username (Foreman) and password.
4. Press
to edit settings.
5. Machine Name: Enter the name of the machine.
6. MillMaster Link: Select “On”.
7. Confirm with
.
ð
The settings are saved.