ANNEX
56
Connecting the I/O Robot Junction Box IDH 2182205 for RB40 Robot
The EQ ACCE D-Series Junction Box 24 V, part number 2182205 provides isolated input and
output connections between Loctite 24 Volt D-series robots and external devices such as
solenoids and sensors.
The necessary wiring must be provided by the customer.
Connectors required:
2 Sub-D 9 pin socket
“
fe
male” for XS1
OUT and XS2 Reservoir
1 Sub-D 15 pin plug
“male” for XS10
RD24 Controller
Caution!
The EQ ACCE D-Series Junction Box 24V is only compatible with the Loctite 24-volt RB15,
RB20 and RB40 D-Series robots.
Do not connect EQ ACCE D-Series Junction Box 24V to any other Loctite Robots.
Note
For the connection of further accessories such as sensors for part detection or safety light
curtains please refer to the manuals of the EA ACCE D-Series Junction Box and the used EQ
RB40 robot.
GND Block
use any Position
XS1 Out (upper)
9 COM
1 NO
+24 V Block
use any Position
XS10 RD24 Contr.
2 GND
7 Ready
5 Fill Level empty
3 Start
XS2 Reservoir
e. g. 97108,
97631
1 Refill
2 Empty
5 GND
9 +24 V
TB6-4 Input
Dispenser ready
JP2-4 set
JP6 PNP
Summary of Contents for EQ RC24 RD
Page 2: ......
Page 3: ...3 Inhalt Content Deutsch 4 English 32 ...
Page 29: ...ANHANG 29 Anwendungsbeispiel ...
Page 30: ...ANHANG 30 Konformitätserklärung ...
Page 31: ...31 ...
Page 57: ...ANNEX 57 Application Example ...
Page 58: ...ANNEX 58 Declaration of Conformity ...
Page 59: ......