OPERATING ELEMENTS
48
With the
time monitoring
you can
–
in combination with a shut-off valve
–
limit the
maximum pump running time. This protects the pump.
The function is active, if
-
in the interface settings
the dispense start is set to external and
-
the start is carried out via the external interface XS10 and
-
the value of the time monitoring is not set to 0 s.
The
Flow rate
is used to set the feed rate in ml/min.
With the
retraction
you determine the quantity of the suck-back by the pump after the
dispensing process in order to prevent dripping. If the value is set to 0.0, the suck-back is
deactivated.
Dispense Pump Menu
After opening the dispense pump menu
, the following screen appears:
Here you can choose the pump type of the connected pump.
By tapping on the desired type, all parameters are adjusted accordingly.
Flow rates when using Loctite standard rotor pumps:
Loctite Part No.
Pump
Type
Minimum
Flow Rate
(at 3 RPM)
Maximum
Flow Rate
(at 100 RPM)
Minimum
Dispense Volume
97665EC
Type 6
0.36 ml/min
12 ml/min
0.0075 ml
97669EC/97663EC
Type 8
1.05 ml/min
35 ml/min
0.02 ml
Type 10
for future use
97660EC/97668EC
Type 12
4.95 ml/min
165 ml/min
0.1 ml