- 57 -
PROGRAM SELECTION: confirm
and use the arrow keys to select the desired program:
: basic program, setpoint management only.
: weight remote display program with setpoint.
: monoproduct loading program.
: monoproduct unloading program.
: 3 products batching.
: 6 products batching.
: 14 product batching.
: no program.
Set the weight reading mode (except for
program):
-
: the weight is received either by load cells or intelligent junction boxes or transmitters
connected to the instrument.
-
: the weight is received via serial port (WEIMOD or WEIRIP mode).
Set the approval status (only if
have not been set)
-
: not approved program;
-
: approved program, single interval*;
-
: approved program, multi-interval*;
-
: approved program, multiple range*;
* Contact technical assistance to request the proper manual and the correct procedures for
approval, indicating mandatory hardware code and serial number (see section INSTRUMENT
COMMISSIONING).
Set the active regulation on the instrument (only if
have not been set):
-
: approved program according to EN45501:2015 and OIML R76:2006 for UE;
-
: approved program according to NIST Handbook 44; NCWM PUB 14 for North
America (NTEP).
When a W series instrument is used in combination with an intelligent junction box or a
weight transmitter, the approval status set on both devices must be the same.
Configure the connection to the CLM serie intelligent junction box or to the weight transmitter
(only if
or
have not been set):
-
: intelligent junction box or transmitter connected to the instrument
-
: no intelligent junction box or transmitter connected