![Load Cell Systems WDESK-L Installation And User Manual Download Page 33](http://html1.mh-extra.com/html/load-cell-systems/wdesk-l/wdesk-l_installation-and-user-manual_1932344033.webp)
- 28 -
ZERO TRACKING
(from 1 to 5, default:
): When the weight value is stable and, after a second, it
deviates from zero by a figure in divisions smaller or equal to the figure in divisions set in this
parameter, the weight is set to zero. To disable this function, set
.
Example: if the parameter
is set to 5 and
is set to 2, the weight will be
automatically set to zero for variations smaller than or equal to 10 (
x
).
SETTING UNITS OF MEASURE
These are the available units of measure:
:
kilograms
:
grams
:
tons
:
pounds
: newtons
:
litres
:
bars
:
atmospheres
:
pieces
:
newton metres
: kilogram metres
:
other generic units of measure not included in the list
If the print function is enabled, the symbol corresponding to the selected unit of measure will be
printed after the measured value.
OUTPUTS AND INPUTS CONFIGURATION
OUTPUTS
3 PRODUCTS version:
-
OUTPUTS 1-3: PRODUCTS 1-3.
-
OUTPUT 4: CYCLE END.
6 - 14 PRODUCTS version:
-
OUTPUTS 1-4: refer to relay modules decoding tables (see wiring diagrams and section TEST)
+
+