LIYU PZR-KV-1 Series High Speed
. LIYU-PZR-KV-1-Series Manual
www.liyu-dms.com
- 64 -
4.
Press “MODE” button to enter NO/NC switching interface, and select NO/NC through
▲
and
▼
buttons. We set output 1 as NO and output 2 as NC. The picture below shows the
display interface of the negative pressure gauge.
5.
Press “MODE” button to enter response time setting, and set default time as 2.5. The picture
below shows the display interface of the negative pressure gauge.
6.
Press “MODE” button to enter color conversion setting of the main display, and choose the
color of main display through
▲
and
▼
buttons. The picture below shows the display interface
of the negative pressure gauge.
7.
Press “MODE” button to enter unit setting. The default unit of negative pressure gauge is
shown as KPa, which is the unit we need. Unit could be selected through
▲
and
▼
buttons. The
interface is shown as the picture.
8.
By this time Menu setups have been circled a circle. Press “MODE” button once again to
return. The main display shows actual air pressure values.Or long press “MODE” button for 2
seconds during the setting to return to the home page.
9.
Long press for 5 seconds to enter into “PRO Mode” , under which we only need to set
Hysteresis fixed value as 11.With the default value 111, the negative pressure gauge
fluctuates too frequent in the process of control. Operation procedure: Press “MODE”
button three times, and the interface of the Pressure gauge is shown like this
Through
▲
and
▼
buttons adjust the value to
Long press “
MODE
” button for 5 seconds and return to the home page.
10.
Press“MODE” button to enter P-1 and P-2 value setting, and set the value as the pressure
imposed on the ink-feeding system during normal operation.