LIYU PZR-KV-1 Series High Speed
. LIYU-PZR-KV-1-Series Manual
www.liyu-dms.com
- 58 -
Caution: When adjusting the setting values of the pressure gauge, the interval between your
settings should not exceed 0.2 at best.
Operation is set as an example as follows to demonstrate the setting process.
The vacuum pressure gauge shows
normal negative pressure
The Pressure gauge shows Lo_1 and
its current setting value. Adjust its
into
the
calculated
one
value
following the above
-
said method by
using the up/ down arrow.
The Pressure gauge shows Hi_1 and
its current setting value. Adjust its
v
alue into the calculated one.
The Pressure gauge shows P_2 and its
current setting value. Adjust its value
into the calculated one.
Setting completed
Press “MODE” button
Press “MODE” button
Press “MODE” button