![Littelfuse Startco FPU-32 Manual Download Page 3](http://html1.mh-extra.com/html/littelfuse-startco/fpu-32/fpu-32_manual_1928675003.webp)
Page i
FPU-32 Feeder Protection Unit
Rev.
2-A-103014
Table of Contents
T
ABLE OF
C
ONTENTS
S
ECTION
P
AGE
List of Figures ......................................................................... ii
List of Tables .......................................................................... ii
1 Introduction
.......................................................... 1-1
1.1 General
.....................................................................
1-1
1.2 FPU-32
Features
......................................................
1-1
1.2.1 Protection
.....................................................
1-1
1.2.2 Metering.......................................................
1-1
1.2.3 Data
Logging
...............................................
1-1
1.2.4 Inputs and Outputs ...................................... 1-1
1.2.5 Operator
Interface
.......................................
1-1
1.2.6 Communications
.........................................
1-1
1.3 Ordering
Information
..............................................
1-3
2 Installation
.............................................................. 2-1
2.1 General
.....................................................................
2-1
2.2 FPU-32 Feeder Protection Unit .............................. 2-1
2.3 MPU-CIM Current Input Module .......................... 2-1
2.4 Earth-Fault
CT’s
......................................................
2-1
2.5 FPU-32/FPU-16
Compatibility
..............................
2-1
3 System
Wiring
....................................................... 3-1
3.1 General
.....................................................................
3-1
3.2 Wiring
Connections
................................................
3-2
3.2.1 FPU-32
Connections
....................................
3-2
3.2.1.1 Supply Voltage ............................... 3-2
3.2.1.2 CIM Input ....................................... 3-2
3.2.1.3 Digital Input ................................... 3-2
3.2.1.4 Analog Output ................................ 3-2
3.2.1.5 PTC or RTD Input ......................... 3-2
3.2.1.6 I/O Module Communications ........ 3-2
3.2.1.7 RS/EIA/TIA-232
Communications ........................... 3-3
3.2.2 MPU-CIM
Connections
..............................
3-3
3.2.2.1 Standard
.........................................
3-4
3.2.2.2 Residual
Earth-Fault
.....................
3-4
3.2.2.3 Two-CT
.........................................
3-4
3.2.3 Cable
Restraint
............................................
3-6
3.2.4 Dielectric-Strength
Testing
.....................
3-6
4
Operation and Setup
............................................. 4-1
4.1 Display
and
Indication
............................................
4-1
4.1.1 Front-Panel LED Indication ....................... 4-1
4.1.2 Rear-Panel LED Indication......................... 4-2
4.1.3 Display Contrast and Test ........................... 4-2
4.2 Setup
.......................................................................
4-2
4.2.1 Phase-CT
Inputs
..........................................
4-2
4.2.2 Earth-Fault-CT
Input
...................................
4-2
4.2.3 Frequency
....................................................
4-2
4.2.4 Set-Point
Group
...........................................
4-2
4.2.5 Output
Relay
Assignment
...........................
4-2
4.2.6 Digital
Input
.................................................
4-3
4.2.7 Analog
Output
.............................................
4-3
4.2.8 Miscellaneous Configuration ...................... 4-4
4.2.9 Communications
.........................................
4-4
4.3 Metering ............................................................. 4-4
S
ECTION
P
AGE
4.4 Messages
.................................................................
4-5
4.4.1 Trip
Reset
....................................................
4-5
4.4.2 Data
Logging
..............................................
4-5
4.4.3 Statistical
Data
............................................
4-5
4.4.4 Emergency
Thermal
Reset
.........................
4-5
4.5 Password Entry and Programming ..................... 4-5
5 Protective
Functions
......................................... 5-1
5.1 General
...............................................................
5-1
5.2 Overload
.............................................................
5-1
5.2.1 I
2
t Protection ........................................... 5-1
5.2.2 Emergency Thermal Reset ...................... 5-2
5.3 Inverse-Time
Overcurrent
..................................
5-2
5.4 Definite-Time Overcurrent
...............................
5-12
5.5 Inverse-Time
3I
0
Earth Fault ............................ 5-12
5.6 Definite-Time 3I
0
Earth Fault ........................... 5-12
5.7 Definite-Time Earth Fault ................................ 5-13
5.8 Current
Unbalance
............................................
5-13
5.9 Phase
Loss ........................................................ 5-13
5.10 Phase
Reverse
...................................................
5-13
5.11 PTC
Temperature
.............................................
5-13
5.12 RTD
Temperature
............................................
5-14
6
Theory of Operation
......................................... 6-1
6.1 Signal-Processing
Algorithms
............................
6-1
7 Communications
............................................... 7-1
7.1 Personal-Computer
Interface
..............................
7-1
7.1.1 Firmware
Upgrade
..................................
7-1
7.1.2 SE-Comm-RIS
........................................
7-1
7.2 Network
Interface ............................................... 7-1
7.2.1 TIA-485
Option
.......................................
7-1
7.2.2 DeviceNet
Option
...................................
7-1
7.2.3 Ethernet Option ....................................... 7-1
8 Technical
Specifications
................................... 8-1
8.1 FPU-32
...............................................................
8-1
8.2 Current Input Module (MPU-CIM) .................... 8-3
9 Warranty
........................................................... 9-1
Appendix A FPU-32 Menu Map
................................ A-1
Appendix B FPU-32 Set-Up Record
.......................... B-1
Appendix C FPU-32 TIA-232 Modbus Protocol
...... C-1
Appendix D Communications Database Table
........ D-1
Appendix E Register Formats
................................... E-1
Appendix F Ground-Fault Performance Test
.......... F-1
Appendix G FPU-32 Revision History
...................... G-1