iGrow 1800 Installation Guide
Page71
Link4 (714) 524-0004
Now we will go through and show you how to program each of the equipment types listed above.
ON/OFF Equipment
02 ExFan OnOff
Heat Cool
654321 N 123456
000000 0 011111
The iGrow 1600/1800™ supports On/Off devices with up to 6 heating and 6 cooling stages. 1 to turn equipment
ON and 0 to turn it OFF. Use the
+
or
–
keys to toggle the On/Off condition for a particular stage.
In the above example, we have the exhaust fan coming on beginning with the second stage of cooling and then
continuing on in the remaining six cooling stages.
Note:
If in the Cooling/Heating Stage setup you selected fewer than 6 stages, then only the number of stages
that you selected will appear for the On/Off devices and Vents (Refer to Cool/Heating Stages Setup to set
how many stages are desirable).
This second screen can be programmed for various applications which we will discuss below.
02 ExFan OnOff
No Pump
AC Override
Disabled
For now we will leave the default, No Pump and leave the Active Cooling (AC) Override Disabled.
Editing Note
: If you have already programmed a channel and wish to change either the name or the
equipment type you can do so as follows:
Go to the
Program Equipment
screen, press
Enter
to highlight a channel. Press
+ or –
keys to
select the channel that you want to edit. Then press the
Prev
button to edit the equipment type and
press
Prev
again to edit the equipment name.