iGrow 1800 Installation Guide
Page48
Link4 (714) 524-0004
Main Status Screen
COOL2 SetPt 72.0+
InT 75.0°F RelHum
OutT 95.3°F 42% dh1
12:34P Tue 07/05/05
The main status screen displays the current status of your greenhouse zone. The numbers shown are only
sample numbers and will differ for each user, but a description for each display will be explained.
Note
: Use the
NEXT
and
BACK
buttons to scroll through Status Screens.
Cool 2
This is the current temperature stage. It can go from Cool 6, to Normal, to Heat 6.
SetPt
This is the current setpoint for cooling, or if it’s in a heat stage, it will be the heat setpoint. For the Normal stage
both the lower and upper setpoints are shown, respectively.
Note:
A + sign after the SetPt reading (72.0+) indicates Heat Boost condition. Please refer to the
Dehumidification/Humidification section for a description on Heat Boost.
InT
This is the current indoor temperature reading from the indoor temperature sensor.
OutT
This is the current outdoor temperature reading, if you have an outdoor temperature sensor.
RelHum
This is the current humidity reading in the zone
dh1
This is the current dehumidification stage. The possible entries are (dh1, DH1, dh2, DH2, dhlt, DHLT, h, H, and
blank). Blank means that the humidity level is acceptable. If this field is highlighted, it means that the iGrow
1600/1800™ is in the dehumidification override mode.
Since the dehumidification control can be programmed to cycle on and off (See Dehumidification/Humidification
Section), the DH1 status indicator can cycle between DH1 and dh1, indicating that the dehumidification process
is on and off, respectively.
The last line displays the current
time, day of the week and date