Subject to modifications
Page 8 of 12
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
User Manual
Operating Instructions
2.6EN-20005-E09
PCB 10 Components of the control p.c.b. H
000024 40a
To check whether voltage is applied to the printed circuit
board , observe whether the left-hand LED 1 (Fig. PC B 10 )
is lit.
Â
Press illumina ted pu sh button 4 > 2 seconds un til the right-
hand LED 3 lights u p.
A sho rter p ause time e lapses, followed by a lubrica tin g
time with the se t duration.
Additional lubrications can be triggere d at any time.
Precondition: Power supply is switched on.
1 -
LED, left-hand
2 -
Rotary switch, red
3 -
LED, right-hand
4 -
Illuminated pushbutton
Repair
PCB 11
Control unit
200024 56a
1 - Rotary switch, red
2 - Shock sensor in metal design
3 - Capacitor
4 - Part number
5 - Terminal
6 - Illuminated pushbutton
1 013A94
CAUTION !
Shock se nsors of prior control p.c.b.s con-
t ain mercury (Fig . PCB 11 ).
I n the case of a repair take care that the
sensor is not damaged as the re would be
t he risk of harmful va pours.
Â
Remo ve the d efective cont rol p.c.b.
Â
Pack the defective con trol p. c.b . properly so t hat it will
reach the factory witho ut any fu rther damages.
Â
(…)
Â
Conn ect the n ew control p.c.b. an d install it properly.
6001 a02
I MPORTANT
Whe never the pump housing has been
o pened (e. g. for repla cing of the p .c.b .), the
h ousing cove r (including the foa med sea l)
must be replaced.