Time Setting
PCB 7
Cover lid to the control PCB
000 02617a
Â
To set the pause o r lubrica ting time, remo ve the cover on
the pump housing.
6001 a02
I MPORTANT
Up on comple tion of th e time setting, make
sure to firmly close the co ver lid again.
PCB 8
Rotary switch – lubricating time
200024 31
Factory setting
Lubricating time ……… …………………. 6 minutes
Stand-by time ……………………………. 6 hours (fixed)
To set the lubricating tim e
The lubricating time can be set to 15 differe nt settings by
means of the red rotary switch.
6001 a02
IMPORTANT
The 0 se ttin g has no function
.
Switch position
1
2
3 4 5 6 7 8 9 A B C D E F
Mi nutes
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Test / To trigger an additional lubrication
PCB 9
Shock sensor
200024 50a
Â
Conn ect the trailer t o the tractor u nit.
Â
Switch on the driving switch.
Â
Keep the brake
actuated!
Â
Slightly push t he pu mp causing the shock sensor (Fig.
PCB 9) actuat es the stand-b y time.