Safety Instructions
Appropriate Use
Use the 203 pump only for dispensing lubricants in cen-
tralized lubrication systems. The pump is designed for in-
termittent operation.
Misuse
Any use of the 203 Pump that is not expressly mentioned in
this Owner Manual will be regarded as misuse.
If the 203 pumps used or operated in a different manner other
than specified, any claim for warranty or liability will be null and
void.
6001a02
NOTE
If personal injury or material damage
occurs as a result of inappropriate opera-
tion, e.g. if the safety instructions are
ignored or resulting from an incorrect
installation of the 203 pump, no claims or
legal actions may be taken against
Lincoln GmbH.
General Safety Instructions
Quicklub centralized lubrication systems
- are designed state-of-the-art.
- can be assembled for safe operation.
- must be filled regularly without air inclusions with clean
lubricant recommended by the manufacturer.
Incorrect use may result in bearing damage caused by
poor or over-lubrication.
Unauthorized modifications or changes to an installed
system are not admissible. Any modification must be
subject to prior consultation with the manufacturer of the
lubrication system.
Regulations for Prevention of Accidents
To prevent accidents, observe all city, state and federal
safety regulation of the country in which the product will be
used.
Avoid the operation with
- unapproved parts.
- insufficient or contaminated lubricants.
Disposal
Dispose of used or contaminated lubricants as well as of
parts that were in touch with lubricant according to the legal
regulations pertaining to environmental protection. Make
sure to observe the safety data sheets of the lubricants
used.
Exclusion of Liability
The manufacturer of the pump 203 will not accept any liability
for damages:
caused by a lack of lubricant due to an irregular refilling of
the pump.
caused by the use of contaminated lubricants.
caused by the use of greases which are not or only condi-
tionally pumpable in centralized lubrication systems (see
pages 27 ff).
caused by chemical or biological modifications of the
lubricant used.
caused by inadequate disposal of used or contaminated
lubricants as well as of components that have been in
touch with lubricant.
caused by unauthorized modification of the system com-
ponents.
caused by the use of unapproved parts.
Operation, Maintenance and Repair
Repair should only be performed by authorized and in-
structed personnel who are familiar with the instructions.
Lincoln Quicklub centralized lubrication systems
- must be operated only with installed pressure relief
valve.
- must be refilled in regular intervals with clean lubricant
recommended by the manufacturer without air entrap-
ments.
- operate automatically. However, a regular check (approx.
every 2 days) should be made to ensure that lubricant is
emerging from all lubrication points.
1013A94
ATTENTION!
Risk of bursting if the reservoir is
overfilled!
When filling the reservoir by means of
pumps with a large delivery volume
do not exceed the max. filling mark.