Subject to modifications
Owner Manual
Technical Description
2.1A-30001-H07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Page 15 of 36
Mode of Operation, continuation
4159a98
Fig. 14
Sectional view: adjustable element
1 -
adjusting spindle SW 16
(with over flats)
2 -
counternut SW 24
3 -
pump element body
4 -
gasket
5 -
pump cylinder
6 -
control piston
7 -
delivery piston
S -
dimension
4179a99
Fig. 15
Supply diagram
A -
Lubricant output cm
3
/min
B -
Lubricant output cm
3
/stroke
S -
Dimension
Setting of adjustable pump elements
Â
Unscrew the coupling nut for fixing the safety valve.
Â
Loosen counter nut (pos. 2
1)
) while holding in position
pump element body (pos. 3) by means of a second wrench.
Â
Change the position of the adjusting spindle (pos. 1) by
means of a wrench.
Â
The dimension “S” (see Fig. 14) for the desired lubricant
output can be ascertained by using the delivery diagram
shown in Fig. 15.
Retrofit adjustment of max. lubricant output
6001a02
NOTE
In order to ensure that the lubricant output
setting will be as exact as possible, first
the actual dimensions “S” of the max.
lubricant output must be ascertained as
follows. The measured difference from
the nominal value 29 must be considered
for all other settings values (e.g. ± 0.1).
Â
Unscrew the adjusting spindle (pos. 1
1)
) from the pump
element body (pos. 3) until “S” is approx. 30 mm.
Â
Screw counter nut (2) onto stop collar of the adjusting
spindle (pos. 1)
Â
Screw adjusting spindle (pos. 1) with counter nut (pos. 2)
into pump element body (pos. 3) until stop.
1)