Lincoln Quicklub 203 Series Owner'S Manual Download Page 34

Subject to  modifications

Owner Manual

Technical Description

2.1A-30001-H07

Page 34 of 36

LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Lincoln List of Lubricants, continuation 

 

6001a02 

IMPORTANT 

Use lubricants with solid matter additives only after having consulted the manufacturer of the sys-
tem! 

 

Biodegradable lubricants 

Proven lubricants: 

Manufacturer 

Designation 

Thickener 

min. delivery temperature 

ARAL 

Aralub BAB EP 2 

Li/Ca 

-25 °C 

BP 

Biogrease EP 2 

Li/Ca 

-25 °C 

FUCHS-LUBRITECH 

Stabyl ECO EP 2 

Li/Ca 

-25 °C 

 
Lubricant recommendations based on the manufacturer’s data sheet: 

Manufacturer 

Designation 

Thickener 

min. delivery temperature 

AUTOL 

Top Bio 2000 

Ca 

-25 °C 

AVIA 

Biogrease 1 

Li 

up to 0 °C 

DEA 

Dolon E 2 

Li 

-15 °C 

FUCHS 

Plantogel 2 S 

Li/Ca 

-15 °C 

KLÜBER Klüberbio 

M72-82 

Polycarbamide 

-20 

°C 

 

Lubricants for the food & beverage industry 

Lubricant recommendations based on the manufacturer’s data sheet: 

Manufacturer 

Designation 

Thickener 

min. delivery temperature 

ARAL EURAL 

Grease EPF 2 

Al-complex 

-5°C 

BREMER & LEGUIL 

Rivolta F.L.G 4 – 2 

Al-complex 

-20 °C 

ELKALUB 

GLS 364 

organic thickener 

-10 °C 

ELKALUB 

GLS 367/N2 

inorganic thickener 

-5°C 

ELKALUB 

GLS 380/N1 

Al-complex 

-10 °C 

ELKALUB GLS 

380/N2 

Al-complex 

-5°C 

FUCHS 

Renolit G 7 FG 1 

Bentonite 

-5°C 

FUCHS-LUBRITECH 

Gleitmo 585 M (KTW-drinking water release) 

Li 

-10 °C 

INTERFLON 

Fin Food Grease EP 

Al-complex 

-5°C 

KLUEBER 

Paraliq GA 343 

Al-complex 

-10 °C 

KLUEBER 

Kluebersynth UH1 14-151 

Al-complex 

-20 °C 

MOBIL 

Mobilgrease FM 462 

Al-complex 

-15 °C 

Nordischer Maschinenbau 
BAADER 

Special grease GLS 380/N3 

Al-complex 

-5°C 

OKS 470 

Li-12-OH-stearat 

-15 

°C 

OPTIMOL 

Obeen UF 1 

Al-complex 

-15 °C 

OPTIMOL 

Obeen UF 2 

Al-complex 

-10 °C 

RHENUS NORPLEX 

AFD 2 

Al-complex 

-5°C 

RHENUS NORPLEX 

AFP 2 

Al-complex 

-5°C 

RHENUS NORPLEX 

AFS 2 

Al-complex 

-25 °C 

RHENUS NORPLEX 

AFW 2 

Al-complex 

-5°C 

SHELL 

Cassida Grease EPS 1 

Al-complex 

-15 °C 

SHELL 

Cassida Grease EPS 2 

Al-complex 

-10 °C 

TOTAL 

Lubriplate FGL 2 

Al-complex 

-5°C 

TRIBOL MOLUB-ALLOY 

FoodProof 823-2 FM 

Al-complex 

-15 °C 

TRIBOL MOLUB-ALLOY 

9830 high-temperature grease 

PTFE 

0°C 

 

Summary of Contents for Quicklub 203 Series

Page 1: ...ct to modifications Owner Manual Technical Description 2 1A 30001 H07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Quicklub Pump Model 203 for direct current VDC 100...

Page 2: ...6227 33 0 Fax 49 6227 33 259 All rights reserved Any duplication of this User Manual in its entirety or in part by whatever means is prohibited without the prior consent in writing of Lincoln GmbH Sub...

Page 3: ...l 15XN1 15XL1 15XBF2 1 Filling from the top or bottom 2 Filling only from the bottom 3 Filling only from the top 4l 8l with lockable reservoir lid option Low level control option possible with all re...

Page 4: ...ofit adjusting of small lubricant outputs 16 Pressure relief valve 16 without grease return 16 with grease return optional 16 Return line connection 17 Control unit 17 Low level control for grease 18...

Page 5: ...struction User s Responsibility To ensure the safe operation of the unit the user is responsi ble for the following 1 The pump system shall be operated only for the in tended use see next chapter Safe...

Page 6: ...he product will be used Avoid the operation with unapproved parts insufficient or contaminated lubricants Disposal Dispose of used or contaminated lubricants as well as of parts that were in touch wit...

Page 7: ...haulage of hazardous materials valid for Europe ADR 1 and that valid for the Federal Republic of Ger many GGVS 2 2 Moreover the pump and its electrical equipment comply with the regulations of annex B...

Page 8: ...ng switches the negative conductor must be able to be interrupted For avoidance of short circuits please note the following current return lines must be insulated they must be connected to the vehicle...

Page 9: ...cription 2 1A 30001 H07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Page 9 of 36 Installation continuation Mounting of the Pump Areas of Risk continuation 4332a01 F...

Page 10: ...ontrol for triggering an additional lubrication cycle 2A1 1A6 1A7 design and number of pump elements design and number of pressure relief valves filling type use of return line connections low level c...

Page 11: ...2 plug 24 24 VDC square type plug bayonet plug M12 plug AC 120 230 VAC square type plug 5 Number of electric connecting possibilities on pump housing only 1A 1 connection DC AC 5 1A power supply only...

Page 12: ...is designed for the automatic lubrication of the connected lubrication points is designed for the delivery of greases up to NLGI 2 at temperatures from 25 C to 70 C or of mineral oils of at least 40 m...

Page 13: ...Piston diameter K6 standard 6 mm Lubricant output approx 2 8 cm min Piston diameter C7 7 mm Lubricant output approx 4 cm min Piston diameter B7 7 mm Lubricant output approx 2 cm min Piston diameter K...

Page 14: ...pump elements Arrangement of the pump elements If several pump elements are to be installed the installation arrangement shown in Fig 12 must be adhered to If there is only one pump element it can be...

Page 15: ...3 by means of a second wrench Change the position of the adjusting spindle pos 1 by means of a wrench The dimension S see Fig 14 for the desired lubricant output can be ascertained by using the deliv...

Page 16: ...limiting valve The pressure relief valve limits the pressure build up in the system opens at an overpressure of 250 or 350 bar depending on the safety valve design If lubricant is leaking at the pres...

Page 17: ...t Return Line Connection 10032618 Fig 19 Return line connection The lubricant quantities which cannot be dispensed by the metering device must be returned to the pump via the re turn line connection F...

Page 18: ...d solenoid with the pivoting guiding plate automatically outwards in the direc tion of the reservoir wall When leaving the control cam the lubricant presses against the guiding plate and moves the sol...

Page 19: ...elative to the maximum switch ing capacity refer to strictly resistive loads which cannot be always guaran teed in practice it is necessary to take the corresponding contact protection measures in the...

Page 20: ...p reservoir 6593b06 Fig 27 Manual bottom filling of pump reservoir 2 l 4 l 8 l reservoirs Fill the reservoir up to the Max mark via the filling nipple see Fig 26 via the filling fitting for cartridges...

Page 21: ...rational Test Triggering an Additional Lubrication Cycle To check the pump operation it is possible to perform an additional test Refer to the Technical Description of the respective printed circuit b...

Page 22: ...ng fre quency depends on the speed of the motor Reservoir empty Fill up the reservoir with clean grease or oil Allow pump to run trigger an additional lube cycle until the lubricant is sues from all t...

Page 23: ...element with adjustable lubricant output KR 0 04 to 0 18 cm stroke 0 7 to 3 cm min Connection thread G 1 4 in suitable for tube DIA 6 mm suitable for tube DIA 8 mm 6001a02 IMPORTANT The lubricant outp...

Page 24: ...are type connectors DIN 43650 A A Pump housing B Plug 1 C Line socket 1 with connecting cable 5 core if necessary cut off black cable alternatively connecting cable from the user D Plug 2 1 E Line soc...

Page 25: ...control unit connection bayonet plug without low level control A Pump housing B Plug 1 C Line socket 1 with connecting cable 4 2 core M Electric motor 6569a06 Fig 32 Connection diagram Quicklub P 203...

Page 26: ...Manual Technical Description 2 1A 30001 H07 Page 26 of 36 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Technical Data continuation Dimensions 2 l Reservoir 1166a95 F...

Page 27: ...iption 2 1A 30001 H07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Page 27 of 36 Technical Data continuation Dimensions 2 l Reservoir with Filling from Top 1167a95 F...

Page 28: ...hnical Description 2 1A 30001 H07 Page 28 of 36 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Technical Data continuation Dimensions 2 l Flat Type Reservoir 1168a95 F...

Page 29: ...Manual Technical Description 2 1A 30001 H07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Page 29 of 36 Technical Data continuation Dimensions 4 l Reservoir 1169a95 F...

Page 30: ...Manual Technical Description 2 1A 30001 H07 Page 30 of 36 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Technical Data continuation Dimensions 8 l Reservoir 1170a95 F...

Page 31: ...69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Page 31 of 36 Technical Data continuation Attaching Boreholes of the 2 l 4 l 8 l Pump 1171b03 Fig 38 Attaching Boreholes of the 2 l 4 l 8 l Pump 6001...

Page 32: ...raphite that are transportable in lubrication systems only conditionally The lubricants released by us have not been tested with re gard to their long term behavior 6001a02 IMPORTANT The manufacturer...

Page 33: ...2 EP Li 20 C DEA Glissando 20 Li 12 OH stearat 15 to 10 C ESSO Ronex Extra Duty 2 Li complex 5 C ESSO Ronex MP2 Li complex 5 C ESSO Beacon EP2 Li 5 C ESSO Cazar K2 Ca 15 C FIAT LUBRIFICANTI Comar 2 Li...

Page 34: ...anufacturer Designation Thickener min delivery temperature ARAL EURAL Grease EPF 2 Al complex 5 C BREMER LEGUIL Rivolta F L G 4 2 Al complex 20 C ELKALUB GLS 364 organic thickener 10 C ELKALUB GLS 367...

Page 35: ...Subject to modifications Owner Manual Technical Description 2 1A 30001 H07 LINCOLN GmbH Postfach 1263 D 69183 Walldorf Tel 49 6227 33 0 Fax 49 6227 33 259 Page 35 of 36 Note...

Page 36: ...ne Lincoln Way St Louis MO 63120 1578 USA Phone 1 314 679 4200 Fax 1 800 424 5359 Lincoln GmbH Heinrich Hertz Stra e 2 8 69190 Walldorf Germany Tel 49 6227 33 0 Fax 49 6227 33 259 Lincoln Industrial C...