Operating mode
Important
: The operating mode is accessible only during
the pause time, and cannot be operated during the running
time (pump operating time).
Precondition: when the voltage supply is applied, the
decimal point On/h is lit.
Operating option: initiating an additional lube cycle
* Press the button. The elapsed pause time is reset. The
operating time starts. A rotating segment is visible on
the display during the whole operation time.
Operating option: read information on how to set the
pause time and remaining pause time.
* Press the button.
Note: The following display sequence is shown
twice
and is
cancelled after 60 seconds. The change of display occurs
every two seconds. Example:
PP = 12h 30min
rP = 5 h 10 min
PP
(set pause time)
12 .
(hours)
. 30
(minutes)
rP
(remain pause time)
5 .
(hours)
. 10
(minutes)
occurs after second sequence.
Display
press
after 2 sec.
after 2 sec.
after 2 sec.
after 2 sec.
after 2 sec.
after 60 sec.