![Lincoln Impinger 3240 Series Installation, Operation And Maintenance Manual Download Page 9](http://html1.mh-extra.com/html/lincoln/impinger-3240-series/impinger-3240-series_installation-operation-and-maintenance-manual_1917793009.webp)
Part Number 11020000499 Rev B (1/17)
9
Section 2
Installation
Specifications – Models with Electric Heat
Utility Specifications Required – Electric
Model
Energy
Power
Voltage
Current
Phase
Hz
Recommended Electrical
Specifications
3240‑xxx‑B‑Kxxxx
Electric
24 kW
400/230 VAC
40 Amps
3
50 Hz
4 Wires, 3 Pole
1N + 1G
3240‑xxx‑D‑Kxxxx
Electric
24 kW
380/220 VAC
41 Amps
3
50 Hz
4 Wires, 3 Pole
1N + 1G
3240‑xxx‑G‑Kxxx
Electric
24 kW
415/240 VAC
38 Amps
3
50 Hz
4 Wires, 3 Pole
1N + 1G
3240‑xxx‑R‑Kxxxx
Electric
24 kW
208 VAC
66 Amps
3
60 Hz
3 Wires, 3 Pole + G
3240‑xxx‑V‑Kxxxx
Electric
24 kW
240 VAC
58 Amps
3
60 Hz
3 Wires, 3 Poles + G
3240‑xxx‑W‑Kxxxx
Electric
24 kW
220 VAC
63 Amps
3
60 Hz
3 Wires, 3 Poles + G
Electrical Supply for Electric 3240 Ovens in Australia:
Single Phase:
240 VAC, 50 Hz / 20 Amp: one neutral and one earth/ground.
Three Phase:
240/415 VAC / 20 Amp; three active, one neutral and one earth/ground.
All ovens require separate service and dedicated neutral.
n
Warning
These covers MUST be installed on 50 Hz Electric 3240
ovens. It is illegal and potentially dangerous to operate
a 50 Hz Electric oven (any Electric 3240 oven containing
the CE mark) without these covers in place. Not doing
so will cause a liability issue, in the event of an accident.
otice
Do not install the (these) oven(s) in any area with an
ambient temperature in excess of 95°F/35°C. Doing so
will cause damage to the unit(s).