Installation
Section 2
Specifications – Models with Gas Heat
Electrical Service – All Models with Gas Heat
Voltage (AC)
Phase
60 Hz Ovens
120
1
50 Hz Ovens
230/240
1
otice
Do not install the (these) oven(s) in any area with an
ambient temperature in excess of 95°F/35°C. Doing so
will cause damage to the unit(s).
General Information – 3240 atural Gas Ovens
Model
Energy
Power
Voltage
Current
Phase
Hz
Gas Supply
Pressure
Gas Pipe Size
(PT)
Single Oven
Nat. Gas
115,000 BTU/hr
120 VAC
6 Amps
1
60 Hz
8 – 14" W.C.
3/4"
Double Stack
Nat. Gas
230,000 BTU/hr
120 VAC
12 Amps
1
60 Hz
8 – 14" W.C.
1"
Triple Stack
Nat. Gas
345,000 BTU/hr
120 VAC
18 Amps
1
60 Hz
8 – 14" W.C.
1‑1/4"
Single Oven
Nat. Gas
G20
31 kW (HI)
3.88 m
3
/hr
230 VAC
4 Amps
1
50 Hz
2.00 ‑ 3.48 kPa
3/4"
Single Oven
Nat. Gas
G25
26 kW (HI)
3.16 m
3
/hr
230 VAC
4 Amps
1
50 Hz
2.00 ‑ 3.48 kPa
3/4"
Single Oven
Nat. Gas
G25.3
27 kW (HI)
3.13 m
3
/hr
230 VAC
4 Amps
1
50 Hz
2.00 ‑ 3.48 kPa
3/4"
General Information – 3240 Propane Gas Ovens
Model
Energy
Power
Voltage
Current
Phase
Hz
Gas Supply
Pressure
Gas Pipe Size
(PT)
Single Oven
L.P. Gas
115,000 BTU/hr
120 VAC
6 Amps
1
60 Hz
11.5 – 14" W.C.
3/4"
Double Stack
L.P. Gas
230,000 BTU/hr
120 VAC
12 Amps
1
60 Hz
11.5 – 14" W.C.
1"
Triple Stack
L.P. Gas
345,000 BTU/hr
120 VAC
18 Amps
1
60 Hz
11.5 – 14" W.C.
1‑1/4"
Single Oven
L.P. Gas
G30
37 kW (HI)
2.315 kg/hr
230 VAC
4 Amps
1
50 Hz
2.85 – 3.48 kPa
3/4"
Single Oven
L.P. Gas
G31
31 kW (HI)
1.14 m
3
/hr
2.545 kg/hr
230 VAC
4 Amps
1
50 Hz
2.85 – 3.48 kPa
3/4"
Gas Pressure Conversion Chart
Inches of Water
Column
kPa
m-Bar
Millimeters of
Water Column
3.5
0.87
8.7
88.9
4.5
1.12
11.2
114.3
7
1.74
17.4
177.8
10
2.48
24.87
254.0
10.5
2.61
26.11
266.7
11
2.73
27.36
279.4
14
3.48
34.81
355.6
14.5
3.61
36.05
368.3
Electrical Supply for Gas 3240 Ovens in Australia:
Single Phase:
240 VAC, 50 Hz / 20 Amp: one neutral and
one earth/ground.
NOTE: In Australia, use a 10 Amp General Purpose Outlet.
All ovens require separate service and decidated neutral.
Specifications
Body: Stainless Steel
Power: Gas and/or Electric
DB Level: ≤ 71dba
Operating Temperature Range:
300°F ‑ 600°F (149°C ‑ 316°C)
NOTE: For proper operation, the gas valve requires a
nominal inlet pressure of 7 inches H
2
O column for natural
gas and 11 inches of H
2
O column for L.P. gas. A minimum
inlet pressure of 1.0 inch of H
2
O above the manifold setting
(NAT. manifold 3.5 inch H
2
O, L.P. manifold 10 inch H
2
O) must
be maintained with no pressure drop from the no load to
full load condition. The maximum inlet pressure must be
maintained at or below 1/2 psig (14.5 inches H
2
O column).
Refer to the chart on the left for pressure conversions.