Page 64 of 76
Manual Hand Crank
The cover over the Allen key socket must be unscrewed before the Allen key can be inserted and
the hand crank operated.
Hand Crank Torque:
6 - 8 Nm
Hand Crank rpm:
Max. 65
The manual hand crank can be used in the case of power failure.
•
The power supply has to be disconnected during manual operation.
•
If the actuator is operated as a Hand crank, it must only be operated by hand, otherwise there is
a potential risk of overloading and hereby damaging the actuator.
•
Actuators with absolute positioning must be initialised after use of the manual handcrank,
because their positioning will be displaced when the power is disconnected.
•
IC actuators is supplied without manual hand crank.
6 mm Allen key