Actuator with endstop signals and absolute positioning - PWM
I/O specifications:
Input/Output
Specification
Comments
Description
The actuator can be equipped with
electronic circuit that gives an analogue
feedback signal when the actuator moves.
See connection diagram,
fig. 8, page 26
Brown
12 or 24VDC (+/-)
12V ± 20%
24V ± 10%
Under normal conditions:
12V, max. 13A
depending on load
24V, max. 9A depending on load
To extend actuator:
Connect Brown to positive
Connect Blue to negative
To retract actuator:
Connect Brown to negative
Connect Blue to positive
Blue
Red
Signal power supply (+)
12-24VDC ± 10%
Current consumption:
Max. 60mA, also when the actuator is
not running
Black
Signal power supply GND (-)
Green
Endstop signal out
Output voltage min. V
IN
- 2V
Source current max. 100mA
NOT potential free
Yellow
Endstop signal in
Violet
Digital output feedback (PNP)
10-90% (Option 5)
20-80% (Option 6)
Output voltage min. V
IN
- 2V
Tole/- 2%
Max. current output: 12mA
Frequency: 75Hz
It is recommendable to have the
actuator to activate its limit switches
on a regular basis, to ensure more
precise positioning
White
Not to be connected
PWM
Summary of Contents for TECHLINE LA33
Page 1: ...Page 1 of 76 LINAK COM TECHLINE Actuator LA33 User manual...
Page 74: ...Page 74 of 76...