Actuator with Parallel
I/O specifications:
Input/Output
Specification
Comments
Green
Endstop signal out
Output voltage min. V
IN
- 2V
Source current max. 100mA
Endstop signals are NOT potential free.
Endstop signals can be configured with
BusLink software according to any
position needed
Yellow
Endstop signal in
Violet
Parallel communication:
Violet cords must be connected together
Standby power consumption:
12V, 85mA
24V, 50mA
No feedback available during parallel
drive
White
Signal GND:
White cords must be connected together
For correct wiring of power GND and
Signal GND see page 37
•
Current cut-offs should not be used as stop function! This might damage the actuator. Current
cut-offs should only be used in emergencies!
•
Current cut-off limits are not proportional with the load curves of the actuator. This means that the
current cut-offs cannot be used as load indicator.
•
There are tolerances on the spindle, nut, gear wheels etc. and these tolerances will have an
influence on the current consumption for the specific actuator.