![Linak TECHLINE LA33 User Manual Download Page 33](http://html1.mh-extra.com/html/linak/techline-la33/techline-la33_user-manual_1916970033.webp)
Page 33 of 76
Actuator with proportional control
I/O specifications:
Input/Output
Specification
Comments
Description
Easy to use interface with integrated
power electronics (H-bridge).
The actuator is speed controlled by means
of a PWM or 4-20mA signal.
Proportional provides a wide range of pos-
sibilities for customisation.
See connection diagram,
fig. 11, page 33
Brown
12-24VDC + (VCC)
Connect Brown to positive
12V ± 20%
24V ± 10%
12V, current limit 15A
24V, current limit 10A
Note: Do not change the power supply
polarity on the brown and blue wires!
Power supply GND (-) is electrically
connected to the housing
If the temperature drops below 0°C,
all current limits will automatically
increase to: 20A for 12V
15A for 24V
Blue
12-24VDC - (GND)
Connect Blue to negative
12V ± 20%
24V ± 10%
Red
Black
PWM:
Signal levels: > 10V = High
< 2V = Low
with reference to power GND (blue)
Equivalent input resistance ≈ 22k
Frequency: Min. 100Hz
Max. 1000Hz
Overcurrent protected, reverse voltage
protected
4-20mA:
Sinking current with reference to power
GND (blue)
Common mode voltage: GND to
V supply
Equivalent input resistance ≈ 135ohm
Overcurrent protected, reverse voltage
protected
M
H-Bridge
RED
BLACK
Prop
Prop
RED
BLACK
IN
V
Prop
RED
BLACK
IN
V
Summary of Contents for TECHLINE LA33
Page 1: ...Page 1 of 76 LINAK COM TECHLINE Actuator LA33 User manual...
Page 74: ...Page 74 of 76...