4.2.3 Pushing the weed burner
After igniting the flame, push off immediately. The distance
between the skids of the combustion chamber and the
ground must be approximately 2 cm. The skids serve
exclusively to protect the combustion chamber from
damage.
4.2.4 Parking off the weed burner for a longer period
of time
Release the switch bracket The gas flow is stopped and
the flame goes out.
Close the gas valve of the gas cylinder.
Pull the switch bracket onto the handlebar tube. The
remaining gas in the hose line can escape.
Let the weed burner cool down before transporting it or
parking it in a well ventilated room.