34
Available in 2 display type, “Vector” and “Dots”.
Vector
to fill the room between the two adjacent sampling points, in dots of vector
Dots
to display sampling points only
The signal displayed in Vector,
In contrast with the same signal displayed in Dots,
XY Mode
Check "XY Mode", the main display area switches to 3-window VIEW mode. In the XY mode window (
upper-left window), the first channel reflects in X axis, the second channel in Y axis.
Note: When the device works in XY Mode, the record length been restricted at 1K points. The record length setting changes
to 1K points automatically.
Persistence
When “Persistence” chosen, the device emulates the persistence display effect of CRO: the originally
captured signal data in fading color, and the new data in fresh color, in cycle, continually.
The option of “Persistence” lasting available in Off, 0.5s, 1s, 2s, 5s, and Infinite, when set in “Infinite”,
the recording point continues to be there, until the persistence lasting option been changed. Press
“Clear”to clear the current persistence.