C. Setup 

1.

 

Depth Units: Meter, Feet, Fathom; value default as "Meter".   

2.

 

Temperature Units: 

; default as"

". 

3.

 

Depth  Offset:  -5  to  5,  is  divided  into  10  grades,  step  size  is  1; 

change as different ship’s drafts. Value default as "0". 
4.

 

Temperature Offset: -5 to 5, is divided into 10 grades, step size is 

1; adjust manually when the detected and the actual temperature are 
different. Value default as "0". 
5.

 

Reset: No, Yes. 

6.

 

Menu Timer: 5-30, divided into 25 grades; the pop-up menu will 

exit  automatically  when  the  timer  pass  the  current  setting  value; 
value default as "15" seconds. 
7.

 

Select  Readouts:  window  1,  window  2  and  window  3,  with:  Off, 

Voltage, Depth and Temperature for each one.   
    Default: Window 1: "Depth"; Window 2: "Off"; Window 3: "Off". 
    Setting  through  left  and  right  key  of  the 

"Four-in-one multi-function key". When the Depth is available, the 
screen  will  flashing  if  no  current    bottom  signals.  When  the 
Voltage  Alarm  is  on,  the  voltage  display  window  will  flash  in  red 
characters if the current input voltage value is less than the voltage 
alarm value. 

8.

 

Language: Chinese & English; default as “Chinese”. 

 

D.View   

1.

 

Sonar  View:  On  /  Off,  current  screen  shows  only  the 

selected sonar return of "sonar frequency". Default as "On". 

2. Sonar Zoom View: On / Off, current screen shows only the 

selected  sonar  return  of  "sonar  frequency".  The  screen  is 
divided  into  left  and  right  parts,  the  parts  size  can  be  set 
manually, as well as the zoom values. Default as "On". 

3.

 

Dual  Sonar  View:  On  /  Off,  dual  windows  for  the  screen 

shows  the  sonar  signal  return  of  transducer.  Default  as 
"On". 

4.

 

Big  Digit  View:  On  /  Off,  current  screen  shows  only  the 

selected sonar return of "sonar frequency", to see depth data, 
voltage and temperature of user’s location easily. Default as "On". 

5.

 

Circular Flas View: On / Off, current screen shows only the selected sonar return of "sonar 

frequency" with the original status. Default as "On". 

6.System Version: On / Off, current screen shows system information. Default as "Off". 
 
 
 
 

Summary of Contents for LCD Fish/Depth Finder

Page 1: ...OU LILLIPUT ELECTRONIC TECHNOLOGY CO LTD ADDRESS Zong Si Road Lan Tian Economic Development Zone Zhangzhou Fu Jian 363005 China TEL 0596 2109323 2109661 FAX 0596 2109611 http www lilliput com cn http...

Page 2: ...computer s power to the off position until the computer is fully booted Please make sure that the power voltage setting has been adjusted to the standard voltage value of the location where the produc...

Page 3: ...3 4 Transducer Installation 6 3 5 Device Cable Interfaces 8 4 Display Windows 9 4 1 Title Screen 9 4 2 Sonar View 9 4 3 Sonar Zoom View 11 4 4 Dual Sonar View 12 4 5 Big Digital View 13 4 6 Circular...

Page 4: ...range up and down range User to adjust the screen split ratio Data recording and playback High sensitivity gain and the gain in shallow water clear bottom echo detection Multiple alarm modes depth vol...

Page 5: ...5 Background colors white blue black 16 Output power 300W 17 Power supply DC 8 5V 24V 18 Working Environment 0 to 50 relative humidity below 95 19 Storage Temperature 20 70 20 Degree of protection IP6...

Page 6: ...5 3 2 Whole Device Installation...

Page 7: ...g location is very important and will affect the measure accuracy of the transducer directly It is recommended to install it on the bilge where the surface is smooth and flat Keep the transducer far a...

Page 8: ...does not tilt 2 Holding the transducer bracket template for the boat to mark the two mounting holes Center of two holes should be parallel to the surface Ensure that the bottom of the template and the...

Page 9: ...8 3 5 Device Cable Interfaces...

Page 10: ...When the sonar signal bounces between the bottom and the surface of the water and back again Use the appearance of the second return to determine bottom hardness Hard bottoms will show a strong secon...

Page 11: ...white line User set according to personal habits default value white lines 16 Cursor measurements the screen does not pop up in any menu press the four arrow keys in the left right measure Measurement...

Page 12: ...nce back again between the bottom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the seco...

Page 13: ...tom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will di...

Page 14: ...ay the current location of underwater transducer temperature the current water temperature alarm can be set set off according to user needs or display default value off 4 Water surface noise often ref...

Page 15: ...nce to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will display the first sonar return weaker than the second one d T...

Page 16: ...o access the menu system Boot Options menu to view each option in the menu In the boot LOGO if you press the MENU button then the host will start the simulation system In the rest of the system screen...

Page 17: ...as unit 0 to 397 levels step size is 1 and the minimum interval with lower range is 3m B feet as unit 0 to 1302 levels step size is 1 and the minimum interval with lower range is 10 feet C fathom as u...

Page 18: ...ctive immediately long keep press to make step size adjustment effective after release This feature shows location on the screen The upper depth alarm is less than lower depth alarm and different dept...

Page 19: ...ty the more precise data for judge to determine the more detailed data Value default as 5 5 Real time Window Off Standard Wave this feature shows the real times of current sonar return Users can set v...

Page 20: ...gnals When the Voltage Alarm is on the voltage display window will flash in red characters if the current input voltage value is less than the voltage alarm value 8 Language Chinese English default as...

Page 21: ...tcut key to pop up shortcut menu and then adjust the brightness through the left and right keys of Four in one multi function key It s effective immediately through short press and long keep press 2 B...

Page 22: ...View Sonar Zoom View Double Sonar View Big Digit View Circular View Version Information Simulation Depth excursion 5m Shallow water alarm 0 4 30m Depth alarm Upper depth 1 50m Lower depth 2 400m Low v...

Page 23: ...2MM 8 pcs 10 Jack import slot 1 pcs 3 Jack import slot screws KB3 9 2 pcs 11 Device base 1 pcs 4 Line holder screws KB2 3 6 2 pcs 12 Probe line holder 1 pcs 5 Probe rotation axis 1 pcs 13 Hull over th...

Reviews: