background image

 

17 

under  different  units.  Value  default  as  0,  measuring  range  adjustment  according  to  the 
bottom of water. Menu will pop-up through either main menu or shortcut key.   

4.    Chart  Speed  :1-10  levels,  short  press  to  make  step  size  adjustment  effective 

immediately; long-keep press to make step size adjustment effective after release. This 
feature is to adjust the refreshing speed of sonar signal chart. The default value is "5". 

5.    Sonar  Colors:  standard  (composed  of  4  colors  and  32  dominant  hues),  grayscale, 

reversal and green; value default as "standard." 

6-2 Detailed MENU 

A. The alarm MENU 

1. The upper depth alarm: 

  “m”: Off, 1-50 levels, step size is 1, and the minimum interval 

with lower depth is 1m; 
“feet”:  Off,  1-100  levels,  step  size  is  1,  and  the  minimum 
interval with lower depth is 2 feet; 

  “fathom”:  Off,  1-50  levels,  step  size  is  1,  and  the  minimum 

interval with lower depth is 1fathom; 
Short  press  to  make  step  size  adjustment  effective 
immediately;  long-keep  press  to  make  step  size  adjustment 
effective  after  release.  This  feature  shows  location  on  the 
screen. The upper depth alarm is less than lower depth alarm, 
and different depth value under different units. Value default as "off". 

2.    The lower depth alarm:   

  “m”: Off, 3-400 levels, step size is 1, and the minimum interval with lower depth is 1m; 
  “feet”: Off, 10-1312 levels, step size is 1, and the minimum interval with lower depth is 2 

feet; 

  “fathom”:  Off,  3-218  levels,  step  size  is  1,  and  the  minimum  interval  with  lower  depth  is 

1fathom; 

  Short  press  to  make  step  size  adjustment  effective  immediately;  long-keep  press  to  make 

step size adjustment effective after release. The upper depth alarm is less than lower depth 
alarm, and different depth value under different units. Value default as "off". 

3.    Fish ID Alarm: 

  If  you  set  the  large  fish  alarm,  alarm  will  make  sound  when  large  fish  detected.  Value 

default as "off". 

 

 
4.    Low voltage alarm: off, 8.5v-13v interval of 0.5v as a step size. After setting the alarm, if 

the voltage is less than the current set value, it will be in red font and flashing on the screen. 

Summary of Contents for LCD Fish/Depth Finder

Page 1: ...OU LILLIPUT ELECTRONIC TECHNOLOGY CO LTD ADDRESS Zong Si Road Lan Tian Economic Development Zone Zhangzhou Fu Jian 363005 China TEL 0596 2109323 2109661 FAX 0596 2109611 http www lilliput com cn http...

Page 2: ...computer s power to the off position until the computer is fully booted Please make sure that the power voltage setting has been adjusted to the standard voltage value of the location where the produc...

Page 3: ...3 4 Transducer Installation 6 3 5 Device Cable Interfaces 8 4 Display Windows 9 4 1 Title Screen 9 4 2 Sonar View 9 4 3 Sonar Zoom View 11 4 4 Dual Sonar View 12 4 5 Big Digital View 13 4 6 Circular...

Page 4: ...range up and down range User to adjust the screen split ratio Data recording and playback High sensitivity gain and the gain in shallow water clear bottom echo detection Multiple alarm modes depth vol...

Page 5: ...5 Background colors white blue black 16 Output power 300W 17 Power supply DC 8 5V 24V 18 Working Environment 0 to 50 relative humidity below 95 19 Storage Temperature 20 70 20 Degree of protection IP6...

Page 6: ...5 3 2 Whole Device Installation...

Page 7: ...g location is very important and will affect the measure accuracy of the transducer directly It is recommended to install it on the bilge where the surface is smooth and flat Keep the transducer far a...

Page 8: ...does not tilt 2 Holding the transducer bracket template for the boat to mark the two mounting holes Center of two holes should be parallel to the surface Ensure that the bottom of the template and the...

Page 9: ...8 3 5 Device Cable Interfaces...

Page 10: ...When the sonar signal bounces between the bottom and the surface of the water and back again Use the appearance of the second return to determine bottom hardness Hard bottoms will show a strong secon...

Page 11: ...white line User set according to personal habits default value white lines 16 Cursor measurements the screen does not pop up in any menu press the four arrow keys in the left right measure Measurement...

Page 12: ...nce back again between the bottom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the seco...

Page 13: ...tom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will di...

Page 14: ...ay the current location of underwater transducer temperature the current water temperature alarm can be set set off according to user needs or display default value off 4 Water surface noise often ref...

Page 15: ...nce to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will display the first sonar return weaker than the second one d T...

Page 16: ...o access the menu system Boot Options menu to view each option in the menu In the boot LOGO if you press the MENU button then the host will start the simulation system In the rest of the system screen...

Page 17: ...as unit 0 to 397 levels step size is 1 and the minimum interval with lower range is 3m B feet as unit 0 to 1302 levels step size is 1 and the minimum interval with lower range is 10 feet C fathom as u...

Page 18: ...ctive immediately long keep press to make step size adjustment effective after release This feature shows location on the screen The upper depth alarm is less than lower depth alarm and different dept...

Page 19: ...ty the more precise data for judge to determine the more detailed data Value default as 5 5 Real time Window Off Standard Wave this feature shows the real times of current sonar return Users can set v...

Page 20: ...gnals When the Voltage Alarm is on the voltage display window will flash in red characters if the current input voltage value is less than the voltage alarm value 8 Language Chinese English default as...

Page 21: ...tcut key to pop up shortcut menu and then adjust the brightness through the left and right keys of Four in one multi function key It s effective immediately through short press and long keep press 2 B...

Page 22: ...View Sonar Zoom View Double Sonar View Big Digit View Circular View Version Information Simulation Depth excursion 5m Shallow water alarm 0 4 30m Depth alarm Upper depth 1 50m Lower depth 2 400m Low v...

Page 23: ...2MM 8 pcs 10 Jack import slot 1 pcs 3 Jack import slot screws KB3 9 2 pcs 11 Device base 1 pcs 4 Line holder screws KB2 3 6 2 pcs 12 Probe line holder 1 pcs 5 Probe rotation axis 1 pcs 13 Hull over th...

Reviews: