background image

 

15 

5. Key Button Functions 

F403S user interface consists of a set of easy work with various on-screen views and menus to give 
you flexibility and control over your fishing experience. Your control heads has the following keys: 

1.

 

4-WAY Cursor Control 

 

2.

 

MENU

 

3.

 

VIEW

 

4.

 

EXIT

 

5.

 

POWER

 

 

4-WAY Cursor Control 

Four-in-one multi-function keys: composed of up / down, left / right arrow keys. 
The four keys have different functions under different menus. 
Up / Down key: up and down shift of the cursor in the menu. 
Lift/Right key: 
 

A.

 

Selecting main items in the main menu. 

B.

 

In other sub-menu is to achieve choice, value addition and subtraction. 

C.

 

In  the  absence  of  pop-up  menu  screen,  press  the  left  or  right  button  to 
achieve the measurement function, press the EXIT or VIEW key to release 
the current function. 

 

MENU 

 

MENU key: to access the menu system. Boot Options menu - to view each option in the 

menu.  In  the  boot  LOGO,  if  you  press  the  MENU  button  then  the  host  will  start  the 
simulation system. In the rest of the system screen, press the MENU button will start the 

first pop-up shortcut menu for the current interface; if not disappear in the current menu; press the 
MENU button before the system will enter the main menu. All menu operated by the "Four-in-one 
multi-function key" in the up / down or left / right. In the main menu, press the MENU key is to exit 
the menu. Under normal circumstances: the up / down key is for selecting, the left / right key is for 
setting. 

 

VIEW 

 

VIEW  key:  to  achieve  (Sonar  View,  Sonar  Zoom  View,  Dual  Screen  View,  Large 

Number View, Circular View, System Status Windows) the windows switch. And the 
data of windows will refresh when switch.   

 

EXIT 

 

EXIT key to exit in a single-level menu; to back to last menu in a multi-level menu; 

to  back  to  the  front  window  when  the  menu  window  disappeared  (opposite  function 
with VIEW ). 

Summary of Contents for LCD Fish/Depth Finder

Page 1: ...OU LILLIPUT ELECTRONIC TECHNOLOGY CO LTD ADDRESS Zong Si Road Lan Tian Economic Development Zone Zhangzhou Fu Jian 363005 China TEL 0596 2109323 2109661 FAX 0596 2109611 http www lilliput com cn http...

Page 2: ...computer s power to the off position until the computer is fully booted Please make sure that the power voltage setting has been adjusted to the standard voltage value of the location where the produc...

Page 3: ...3 4 Transducer Installation 6 3 5 Device Cable Interfaces 8 4 Display Windows 9 4 1 Title Screen 9 4 2 Sonar View 9 4 3 Sonar Zoom View 11 4 4 Dual Sonar View 12 4 5 Big Digital View 13 4 6 Circular...

Page 4: ...range up and down range User to adjust the screen split ratio Data recording and playback High sensitivity gain and the gain in shallow water clear bottom echo detection Multiple alarm modes depth vol...

Page 5: ...5 Background colors white blue black 16 Output power 300W 17 Power supply DC 8 5V 24V 18 Working Environment 0 to 50 relative humidity below 95 19 Storage Temperature 20 70 20 Degree of protection IP6...

Page 6: ...5 3 2 Whole Device Installation...

Page 7: ...g location is very important and will affect the measure accuracy of the transducer directly It is recommended to install it on the bilge where the surface is smooth and flat Keep the transducer far a...

Page 8: ...does not tilt 2 Holding the transducer bracket template for the boat to mark the two mounting holes Center of two holes should be parallel to the surface Ensure that the bottom of the template and the...

Page 9: ...8 3 5 Device Cable Interfaces...

Page 10: ...When the sonar signal bounces between the bottom and the surface of the water and back again Use the appearance of the second return to determine bottom hardness Hard bottoms will show a strong secon...

Page 11: ...white line User set according to personal habits default value white lines 16 Cursor measurements the screen does not pop up in any menu press the four arrow keys in the left right measure Measurement...

Page 12: ...nce back again between the bottom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the seco...

Page 13: ...tom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will di...

Page 14: ...ay the current location of underwater transducer temperature the current water temperature alarm can be set set off according to user needs or display default value off 4 Water surface noise often ref...

Page 15: ...nce to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will display the first sonar return weaker than the second one d T...

Page 16: ...o access the menu system Boot Options menu to view each option in the menu In the boot LOGO if you press the MENU button then the host will start the simulation system In the rest of the system screen...

Page 17: ...as unit 0 to 397 levels step size is 1 and the minimum interval with lower range is 3m B feet as unit 0 to 1302 levels step size is 1 and the minimum interval with lower range is 10 feet C fathom as u...

Page 18: ...ctive immediately long keep press to make step size adjustment effective after release This feature shows location on the screen The upper depth alarm is less than lower depth alarm and different dept...

Page 19: ...ty the more precise data for judge to determine the more detailed data Value default as 5 5 Real time Window Off Standard Wave this feature shows the real times of current sonar return Users can set v...

Page 20: ...gnals When the Voltage Alarm is on the voltage display window will flash in red characters if the current input voltage value is less than the voltage alarm value 8 Language Chinese English default as...

Page 21: ...tcut key to pop up shortcut menu and then adjust the brightness through the left and right keys of Four in one multi function key It s effective immediately through short press and long keep press 2 B...

Page 22: ...View Sonar Zoom View Double Sonar View Big Digit View Circular View Version Information Simulation Depth excursion 5m Shallow water alarm 0 4 30m Depth alarm Upper depth 1 50m Lower depth 2 400m Low v...

Page 23: ...2MM 8 pcs 10 Jack import slot 1 pcs 3 Jack import slot screws KB3 9 2 pcs 11 Device base 1 pcs 4 Line holder screws KB2 3 6 2 pcs 12 Probe line holder 1 pcs 5 Probe rotation axis 1 pcs 13 Hull over th...

Reviews: