background image

 

4. Display Window

 

4-1. Title Screen 

Turn on your device F403S by pressing the POWER key. The 
title  screen  is  display  until  the  F403S  begins  operation.  The 
device  will  begin  Normal  or  Simulator  operation,  depending 
on your choice.   
Press MENU to begin Simulator operation. The simulator data 
is available under this mode; however the recording function 
is  unavailable  under  simulator  mode.  Otherwise  it  will  enter 
normal  operating  mode.  In  normal  mode  there,  enter  the  last 
visit of the view interface. 
 

4-2. Sonar View 

1. Sonar Color Bar: Color spectrum indicating low to high sonar 
intensity  returns,  where  red  indicates  high  intensity  and  white 
indicates low intensity, default value: standard. 
2. Real Time Sonar Window: Display the  real time sample data, 
the display mode can be changed, default value: waveforms. 
3.

 

Water Surface Noise: The noise waveforms from Sonar returns. 

4.

 

Sonar Return: First sonar return, it indicates depth of the water 

at present. 
5.

 

Second Sonar Return: When the sonar signal bounces between 

the bottom and the surface of the water and back again. Use the 
appearance  of  the  second  return  to  determine  bottom  hardness. 
Hard  bottoms  will  show  a  strong  second  return,  while  soft 
bottoms will show a very weak one or none at all. 
6.

 

Third  Sonar  Return:  When  the  sonar  signal  bounces  between 

the bottom and the surface of the water and back again. 
7.

 

Window 1: Water depth, can set depth alarm, default value: off. 

8.

 

Window 2: Input Voltage, can set low battery alarm, default value: off. 

9.

 

Window  3:  The  temperature  display,  the  current  location  of  underwater  transducer 

temperature, the current water temperature alarm can be set; set off according to user needs 
or display, default value: off. 

10.

 

On the range: the range of display settings, you can manually set, default value: 0 

11.

 

The following range: Display settings under the scope, you can manually set, default value: 

auto. 

12.

 

Depth contours: with three lines to the screen is divided into several equal portions, you can 

also turn off the menu, default value: off 

13.

 

Background  color:  blue,  white,  black.  Different  background  colors,  font  colors  displayed 

are not the same, default value: blue. 

Summary of Contents for LCD Fish/Depth Finder

Page 1: ...OU LILLIPUT ELECTRONIC TECHNOLOGY CO LTD ADDRESS Zong Si Road Lan Tian Economic Development Zone Zhangzhou Fu Jian 363005 China TEL 0596 2109323 2109661 FAX 0596 2109611 http www lilliput com cn http...

Page 2: ...computer s power to the off position until the computer is fully booted Please make sure that the power voltage setting has been adjusted to the standard voltage value of the location where the produc...

Page 3: ...3 4 Transducer Installation 6 3 5 Device Cable Interfaces 8 4 Display Windows 9 4 1 Title Screen 9 4 2 Sonar View 9 4 3 Sonar Zoom View 11 4 4 Dual Sonar View 12 4 5 Big Digital View 13 4 6 Circular...

Page 4: ...range up and down range User to adjust the screen split ratio Data recording and playback High sensitivity gain and the gain in shallow water clear bottom echo detection Multiple alarm modes depth vol...

Page 5: ...5 Background colors white blue black 16 Output power 300W 17 Power supply DC 8 5V 24V 18 Working Environment 0 to 50 relative humidity below 95 19 Storage Temperature 20 70 20 Degree of protection IP6...

Page 6: ...5 3 2 Whole Device Installation...

Page 7: ...g location is very important and will affect the measure accuracy of the transducer directly It is recommended to install it on the bilge where the surface is smooth and flat Keep the transducer far a...

Page 8: ...does not tilt 2 Holding the transducer bracket template for the boat to mark the two mounting holes Center of two holes should be parallel to the surface Ensure that the bottom of the template and the...

Page 9: ...8 3 5 Device Cable Interfaces...

Page 10: ...When the sonar signal bounces between the bottom and the surface of the water and back again Use the appearance of the second return to determine bottom hardness Hard bottoms will show a strong secon...

Page 11: ...white line User set according to personal habits default value white lines 16 Cursor measurements the screen does not pop up in any menu press the four arrow keys in the left right measure Measurement...

Page 12: ...nce back again between the bottom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the seco...

Page 13: ...tom and the bottom surface use of the second return appearance to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will di...

Page 14: ...ay the current location of underwater transducer temperature the current water temperature alarm can be set set off according to user needs or display default value off 4 Water surface noise often ref...

Page 15: ...nce to determine the hardness of the bottom hard bottom will show the first sonar return stronger than the second one and soft bottom will display the first sonar return weaker than the second one d T...

Page 16: ...o access the menu system Boot Options menu to view each option in the menu In the boot LOGO if you press the MENU button then the host will start the simulation system In the rest of the system screen...

Page 17: ...as unit 0 to 397 levels step size is 1 and the minimum interval with lower range is 3m B feet as unit 0 to 1302 levels step size is 1 and the minimum interval with lower range is 10 feet C fathom as u...

Page 18: ...ctive immediately long keep press to make step size adjustment effective after release This feature shows location on the screen The upper depth alarm is less than lower depth alarm and different dept...

Page 19: ...ty the more precise data for judge to determine the more detailed data Value default as 5 5 Real time Window Off Standard Wave this feature shows the real times of current sonar return Users can set v...

Page 20: ...gnals When the Voltage Alarm is on the voltage display window will flash in red characters if the current input voltage value is less than the voltage alarm value 8 Language Chinese English default as...

Page 21: ...tcut key to pop up shortcut menu and then adjust the brightness through the left and right keys of Four in one multi function key It s effective immediately through short press and long keep press 2 B...

Page 22: ...View Sonar Zoom View Double Sonar View Big Digit View Circular View Version Information Simulation Depth excursion 5m Shallow water alarm 0 4 30m Depth alarm Upper depth 1 50m Lower depth 2 400m Low v...

Page 23: ...2MM 8 pcs 10 Jack import slot 1 pcs 3 Jack import slot screws KB3 9 2 pcs 11 Device base 1 pcs 4 Line holder screws KB2 3 6 2 pcs 12 Probe line holder 1 pcs 5 Probe rotation axis 1 pcs 13 Hull over th...

Reviews:

Related manuals for LCD Fish/Depth Finder