AMx36 • SSI & BiSS C-mode
The Preset value you are allowed to enter depends on the overall set resolution
and must be less than or equal to (
) - 1.
Default = 00 00 00 00 00h
Min. value: 00 00 00 00 00h
Max. value: 0F FF FF FF FFh
NOTE
We suggest setting the preset when the encoder shaft is in stop.
Register
50
51
52
53
54
MSB
…
...
...
LSB
2
35
- 2
32
2
31
- 2
24
2
23
- 2
16
2
15
- 2
8
2
7
- 2
0
PRESET SETTING EXAMPLE
value = 01 86 A0h = 100,000
10
1. First of all you must enable the setting of the
bit of the
register.
2. Enter the desired preset value (01 86 A0 h = 100,000
10
parameter.
3. To save the new Preset value without activating it, you must use the
function in the
register (set “01” in the
register).
4. Otherwise, to both save and activate the new Preset value at the same time,
Save parameters and activate Preset
register (set “02” in the
register).
Function
ADDR
DATA Tx
Setting the Enable
preset bit of the
register
49, bit 2
0
register
50
00
51
00
52
01
53
86
54
A0