![Lika AM 3616/4096BG Series User Manual Download Page 33](http://html.mh-extra.com/html/lika/am-3616-4096bg-series/am-3616-4096bg-series_user-manual_1915910033.webp)
AMx36 • SSI & BiSS C-mode
Device ID
[78 … 7D, ro]
These registers contain the Device ID. Refer also to the order code. Identification
name is expressed in hexadecimal ASCII code.
Register
78
79
7A
7B
7C
7D
Hex
41
4D
49
37
32
xx
ASCII
A
M
I
7
2
x
Registers 78-79 = encoder model (AM = AMx36 model)
Registers 7A-7B = interface (I7 = BiSS C-mode interface)
Register 7C = enclosure (2 = 36 mm diameter enclosure)
Register 7D = software version, see the example
EXAMPLE
If the value in the register 7D is “31” hex, then the software version is “1”.
Manufacturer ID
[7E-7F, ro]
These registers contain the Manufacturer ID. Identification name is expressed in
hexadecimal ASCII code.
Register
7E
7F
Hex
4C
69
ASCII
L
i
Li = Lika Electronic
6.6 Application notes
Data transmission:
Parameter
Value
Clock Frequency
Min 200 kHz, max 10 MHz
BiSS time-out
Self-adaptable to the clock, 10
µs max.
MAN AMx36 SSI_BiSS E 1.1.odt
6 - BiSS C-mode interface
33 of 36