AMx36 • SSI & BiSS C-mode
- Address: the register address is expressed in hexadecimal notation.
- Attribute:
ro = read only
rw = read and write
wo = write only
- Default parameter value is written in
bold
.
Profile ID
[42 - 43, ro]
These registers contain the identification code of the used profile.
Register
42
43
AMx36
00
00
See “Standard encoder profile”, “data format”, “Variant 0-24”.
Serial number
[44 … 47, ro]
These registers contain the serial number of the device expressed in hexadecimal
notation.
Register 44: year of production.
Register 45: week of production.
Registers 46 and 47: serial number in ascending order.
Command
[48, wo]
Value
Function
00
Normal operational state
01
Save parameters on EEPROM
02
Save parameters and activate Preset
04
Load and save default parameters
After having set a new value in some register, use the
register to store it. Set “01” in the
register.
After having set a new value in some registers and a Preset value, use the
parameters and activate Preset
the values and activate the preset at the same time. Set “02” in the
register.
WARNING
If you set a new singleturn or multiturn resolution and a new preset value at the
same time and then use this
Save parameters and activate Preset
MAN AMx36 SSI_BiSS E 1.1.odt
6 - BiSS C-mode interface
25 of 36